Isilon: Cannot Find Disk Provider Error On Reimaging

요약: Cannot find disk provider error can occur when the reimage program cannot find a bootstrap provider.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

증상

The error message "Cannot find disk provider" appears during the reimaging process.

Cannot find disk provider
Traceback (most recent call last):
  File "/root/bin/flashdisk_reimage.py", line 2375, in 
    sys.exit(main(getargs()))
  File "/root/bin/flashdisk_reimage.py", line 2251, in main
    setup_psi(args)
  File "/root/bin/flashdisk_reimage.py", line 1703, in setup_psi
    setup_psi_backup_device(args)
  File "/root/bin/flashdisk_reimage.py", line 1763, in setup_psi_backup_device
    psi_backup_device.providers.init_short()
  File "/root/bin/flashdisk_reimage.py", line 1213, in init_short
    bootdisk.init_providers(wipe=False)
  File "/b/mnt/obj/b/mnt/src/amd64.amd64/isilon/lib/python/stage-3.8/usr/local/lib/python3.8/site-packages/isi/sys/bootdisk.py", line 729, in init_providers
  File "/b/mnt/obj/b/mnt/src/amd64.amd64/isilon/lib/python/stage-3.8/usr/local/lib/python3.8/site-packages/isi/sys/bootdisk.py", line 730, in 
IndexError: list index out of range

The command to confirm the issue is: isi_bootstrap_devices -b, which produces the following output:

isi-bsd# /usr/bin/isi_hwtools/isi_bootstrap_devices -b
name:
isi-bsd#

원인

The cause of this issue is a disk missing in the highest slot number of the A sled for the node.

해결

To resolve the issue, follow these steps:

  • Put a drive into the highest slot number of the A sled for the node. If the drive was removed due to a fault, replace the faulted drive before continuing.
  • If you have a drive in the highest A slot number, swap the drive with another drive in the sled. Once the sled is reseated, attempt the reimage process again.

 

Caution: If you are unsure or concerned about making these changes, contact Dell Support or browse their website for further assistance.
Note: Handle the hardware with care to avoid any damage.

해당 제품

Isilon Gen6, PowerScale A310, PowerScale A3100, PowerScale H710, PowerScale H7100
문서 속성
문서 번호: 000359362
문서 유형: Solution
마지막 수정 시간: 16 7월 2026
버전:  2
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.