PowerEdge R770: Backplane and Cable events during reported during POST
요약: Critical HWC8011 entries for backplane, signal‑power and cable issues appear in System event log on every boot; they persist due to a issue in iDRAC firmware 1.30.30.50 1.30.10.52.
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
SEL and LC Log report various Backplane and Sig Pwr issues.
- Issue only exists in iDRAC firmware 1.30.30.50 and 1.30.30.52. No other iDRAC firmware version is affected.
- Event Code is always HWC8011.
- Severity is always Critical.
Examples:
- HWC8011 - The System Configuration Check operation resulted in multiple Backplane issues.
- HWC8011 - The System Configuration Check operation resulted in multiple Sig Pwr Cable issues.
- HWC8011 - The System Configuration Check operation resulted in multiple Backplane Cable issues.
These events will be present in every boot. The events do not clear on warm boot, cold boot, or AC power cycle. A hardware replacement will not remediate these events.
원인
A supported configuration was inadvertently dropped from iDRAC firmware version 1.30.30.50. The issue is also present in iDRAC firmware version 1.30.30.52.
해결
This issue is resolved in iDRAC firmware version 1.30.30.55.
For customers unable to apply this update, a workaround is available.
- Workaround: Roll iDRAC firmware back to March release (version 1.30.10.50) or May release (version 1.30.10.51).
해당 제품
PowerEdge R770문서 속성
문서 번호: 000491029
문서 유형: Solution
마지막 수정 시간: 03 8월 2026
버전: 2
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.