Data Domain: Disk Unknown

Samenvatting: Disks may show “Unknown” when a new drive isn’t recognized, a failed or unreliable drive reports unknown, a newly added enclosure isn’t integrated, or a replacement disk isn’t initialized. ...

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

  • A disk appears with the state "Unknown" in the system.
  • The issue may affect:
    • A single disk in the system controller (head unit) or attached storage
    • All disks in a newly attached enclosure
    • A disk recently replaced due to failure

Oorzaak

A disk may report as "Unknown" due to one of the following reasons:

  • A newly installed disk is not (yet) recognized by the system.
  • A disk in the system is unreliable (for example, a failed disk reports an 'unknown' state).
  • An entire enclosure has been added but not yet integrated into the RAID group.
  • A single disk replacement has not been properly initialized.

Oplossing

Follow the steps below based on the scenario:

  1. Verify Disk State

  2. Single Disk Reports "Unknown" (and is NOT a new replacement disk)

    • Check active system alerts (alerts show current) and disk state (disk show state)
      • If the disk is reported as failed, and is in an 'unknown' state - replace the 'unknown/failed' disk
    • If the 'unknown' disk is a newly installed (replacement) disk, see Step 4.
  3. All Disks in a New Enclosure Report "Unknown"

    • This is expected behavior for a newly added shelf.
      • Follow the relevant Shelf Hardware Guide to get the 'Unknown' disks added to storage capacity.
    • A basic overview of the steps to add a new shelf: Obtain relevant licensing, add the storage to the required storage tier (active, cloud) and then expand the filesystem,
  4. Single Disk Reports "Unknown" After Replacement

    • Attempt a rescan of drives. From DD-CLI (ssh), Run command # disk rescan
    • Verify status of drive from DD-CLI # disk show state
      • If the disk has become 'In-use' and the alert has not cleared, manually clear the alert using DD-CLI # alerts clear alert-id <alert-id>
      • If the disk remains 'unknown' - run the # disk unfail <encl.disc>  command to transition the disk to a spare state.
  5. Need Additional Assistance

    • If the issue remains unresolved:
      • Contact your contracted support provider and raise a service request.

Extra informatie

 

 

     

    Getroffen producten

    Data Domain

    Producten

    Data Domain
    Artikeleigenschappen
    Artikelnummer: 000043258
    Artikeltype: Solution
    Laatst aangepast: 20 jan. 2026
    Versie:  5
    Vind antwoorden op uw vragen via andere Dell gebruikers
    Support Services
    Controleer of uw apparaat wordt gedekt door Support Services.