Isilon PowerScale: 부팅 중지 조건에 도달하여 이미지 재작성 프로세스가 실패함

Samenvatting: 더티 파티션으로 인해 Isilon 또는 PowerScale 노드를 이미지로 다시 설치할 수 없습니다.

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

Isilon 또는 PowerScale 노드를 이미지로 다시 설치할 때 다음과 유사한 메시지가 표시됩니다.
 

Unable to pull files from None backup
Installation config method is PSF: Unable to pull secondary backup files
Installation config method is PSF: Copying PSI config files
Unable to /sbin/mount /dev/mirror/mfg on /mfg
PSF file path /mfg/psi/psf.json unmounted primary backup; mount attempt failed
stop_boot condition reached, but OneFS install flag set. Aborting.
Failed to copy PSI config files: Chassis is missing a PSI receipt.
A receipt must be provided before the boot will be allowed to continue.
[: -ne: unexpected operator
eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory
eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory
eval: /opt/dell/srvadmin/iSM/bin/Invoke-iSMPKIHelper: not found
Starting background file system checks in 60 seconds.

Thu Mar 28 21:44:58 GMT 2024


Isilon OneFS/amd64 (isi-bsd) (ttyu0)



login:

 

Oorzaak

미러가 이전에 더티로 표시되었으며 파일 시스템 검사를 통해 해결해야 합니다.

Oplossing

루트 사용자 이름과 비밀번호를 사용하여 운영 체제에 로그인한 후 다음을 실행합니다.
 

fsck -y -t ufs /dev/mirror/*

명령에 미러가 복구된 것으로 표시되면 명령을 다시 실행합니다. 미러에서 no changes를 보고할 때까지 명령을 계속 다시 실행합니다.

미러가 정상으로 표시되면 노드를 재부팅하고 이미지 재작성 프로세스가 완료되어야 합니다. 이미지 재작성 프로세스에 문제가 계속 발생하면 지원팀에 문의하십시오.

Getroffen producten

Isilon Gen6.5, Isilon Gen6
Artikeleigenschappen
Artikelnummer: 000223642
Artikeltype: Solution
Laatst aangepast: 02 apr. 2024
Versie:  1
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.