Isilon PowerScale:重新製作映像程序失敗,並達到停止開機條件

Samenvatting: 由於磁碟分割已髒,無法重建 Isilon 或 PowerScale 節點的映像。

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

為 Isilon 或 PowerScale 節點重建映像時,會顯示類似此訊息:
 

Unable to pull files from None backup
Installation config method is PSF: Unable to pull secondary backup files
Installation config method is PSF: Copying PSI config files
Unable to /sbin/mount /dev/mirror/mfg on /mfg
PSF file path /mfg/psi/psf.json unmounted primary backup; mount attempt failed
stop_boot condition reached, but OneFS install flag set. Aborting.
Failed to copy PSI config files: Chassis is missing a PSI receipt.
A receipt must be provided before the boot will be allowed to continue.
[: -ne: unexpected operator
eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory
eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory
eval: /opt/dell/srvadmin/iSM/bin/Invoke-iSMPKIHelper: not found
Starting background file system checks in 60 seconds.

Thu Mar 28 21:44:58 GMT 2024


Isilon OneFS/amd64 (isi-bsd) (ttyu0)



login:

 

Oorzaak

鏡像先前被標記為已髒,需要檔案系統檢查才能解決。

Oplossing

使用 root 的使用者名稱和密碼登入作業系統,然後執行:
 

fsck -y -t ufs /dev/mirror/*

如果命令指示它已修復任何鏡像,請重新運行該命令。繼續重新運行該命令,直到鏡像報告沒有變化。

當鏡像標示為乾淨後,請為節點重新開機,重建映像程序應會完成。如果重建映像程序持續發生問題,請聯絡支援人員。

Getroffen producten

Isilon Gen6.5, Isilon Gen6
Artikeleigenschappen
Artikelnummer: 000223642
Artikeltype: Solution
Laatst aangepast: 02 apr. 2024
Versie:  1
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.