Isilon PowerScale:重新映像过程失败,达到停止启动条件
Samenvatting: 由于脏分区,无法重新映像 Isilon 或 PowerScale 节点。
Dit artikel is van toepassing op
Dit artikel is niet van toepassing op
Dit artikel is niet gebonden aan een specifiek product.
Niet alle productversies worden in dit artikel vermeld.
Symptomen
重新映像 Isilon 或 PowerScale 节点时,将显示类似于以下内容的消息:
Unable to pull files from None backup Installation config method is PSF: Unable to pull secondary backup files Installation config method is PSF: Copying PSI config files Unable to /sbin/mount /dev/mirror/mfg on /mfg PSF file path /mfg/psi/psf.json unmounted primary backup; mount attempt failed stop_boot condition reached, but OneFS install flag set. Aborting. Failed to copy PSI config files: Chassis is missing a PSI receipt. A receipt must be provided before the boot will be allowed to continue. [: -ne: unexpected operator eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory eval: /opt/dell/srvadmin/iSM/bin/Invoke-iSMPKIHelper: not found Starting background file system checks in 60 seconds. Thu Mar 28 21:44:58 GMT 2024 Isilon OneFS/amd64 (isi-bsd) (ttyu0) login:
Oorzaak
镜像之前标记为脏,需要文件系统检查才能解决。
Oplossing
使用用户名 root和密码登录操作系统,然后运行:
fsck -y -t ufs /dev/mirror/*
如果命令指示已修复任何镜像,请重新运行该命令。继续重新运行该命令,直到镜像报告没有更改。
镜像标记为干净后,重新启动节点,重新映像过程应完成。如果重新映像过程仍然存在问题,请联系支持部门。
Getroffen producten
Isilon Gen6.5, Isilon Gen6Artikeleigenschappen
Artikelnummer: 000223642
Artikeltype: Solution
Laatst aangepast: 02 apr. 2024
Versie: 1
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.