How to confirm UCS vHBA timeout settings as part of storage array pre-upgrade checks?
Samenvatting: Location and defaults for UCS fnic VHBA timeout settings.
Dit artikel is van toepassing op
Dit artikel is niet van toepassing op
Dit artikel is niet gebonden aan een specifiek product.
Niet alle productversies worden in dit artikel vermeld.
Instructies
Question
How to confirm UCS vHBA timeout settings as part of storage array pre-upgrade checks?
Facts
- UCS
- UCSM
- vHBA
- Vblock Series 500
- Vblock Series 300
- Vblock Series 700
Answer
The UCS fnic vHBA timeout settings can be viewed in UCSM element manager under Servers > Policies > Adapter Policies, then look for the FC Adapter Policies. By default, VCE will use the FC policies for VMware, Linux, and Windows for ESXi and bare metal service profiles with a default Link Down Timeout of 30,000 ms (30 seconds). This should be sufficient to buffer any failover between array storage controllers during a NDU (non-disruptive upgrade) process.
Getroffen producten
VxBlock and Vblock SystemsProducten
VxBlock and vBlock Systems SeriesArtikeleigenschappen
Artikelnummer: 000204505
Artikeltype: How To
Laatst aangepast: 21 okt. 2022
Versie: 1
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.