Connectrix MDS 系列 Cisco:ISL 退回不会更改 iInterface 上的时间,而是更改逻辑端口通道上的时间
Сводка: 当作为端口通道成员的 ISL 被退回时,逻辑端口通道上的“上次更改”时间戳会更新,但不会在单个物理接口上更新。这是设计的本意。
Данная статья применяется к
Данная статья не применяется к
Эта статья не привязана к какому-либо конкретному продукту.
В этой статье указаны не все версии продуктов.
Симптомы
本文介绍如何解释属于端口通道成员的 ISL 上的链路事件。
作为逻辑端口通道一部分的 ISL 接口在摆动或重置后不会更新“上次更改”时间戳。
ISL 端口 fc3/1 是端口通道 200 的一部分,具有以下“上次更改”时间戳。
mds9513(config-if)# show interface fc3/1 fc3/1 is trunking Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) Port WWN is xx:xx:xx:xx:xx:xx:xx:xx Peer port WWN is xx:xx:xx:xx:xx:xx:xx:xx Admin port mode is auto, trunk mode is on snmp link state traps are enabled Port mode is TE Port vsan is 10 Speed is 4 Gbps <Snip> Belongs to port-channel 200 Trunk vsans (admin allowed and active) (10) Trunk vsans (up) (10) Trunk vsans (isolated) () Trunk vsans (initializing) () <Snip> Interface last changed at Sun Jul 19 20:24:36 2015
端口通道 200 输出:
mds9513(config-if)# sh int po200 port-channel 200 is trunking Hardware is Fibre Channel Port WWN is xx:xx:xx:xx:xx:xx:xx:xx Admin port mode is auto, trunk mode is on snmp link state traps are enabled Port mode is TE Port vsan is 10 <Snip> Member[1] : fc3/1 Interface last changed at Sun Jul 19 20:24:36 2015 mds9513(config-if)# show clock 23:02:18.026 JST Mon Jul 20 2015
ISL 接口链路已关闭并重置,如下所示:
mds9513(config-if)# sh log last 10 2015 Jul 20 23:04:04 mds9513 %PORT-5-IF_TRUNK_DOWN: %$VSAN 10%$ Interface port-channel 200, vsan 10 is down (Gracefully shutdown) 2015 Jul 20 23:04:04 mds9513 %PORT-5-IF_DOWN_NONE: %$VSAN 10%$ Interface port-channel 200 is down (None) 2015 Jul 20 23:04:04 mds9513 %PORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: %$VSAN 10%$ Interface port-channel 200 is down (No operational members)
单个 ISL 端口上的“上次更改”时间戳不会更新:
mds9513(config-if)# sh int fc3/1 fc3/1 is trunking Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) Port WWN is xx:xx:xx:xx:xx:xx:xx:xx Peer port WWN is xx:xx:xx:xx:xx:xx:xx:xx Admin port mode is auto, trunk mode is on snmp link state traps are enabled Port mode is TE Port vsan is 10 <Snip> Belongs to port-channel 200 Trunk vsans (admin allowed and active) (10) Trunk vsans (up) (10) Trunk vsans (isolated) () Interface last changed at Sun Jul 19 20:24:36 2015 ++++ No time change updated.
但是,逻辑端口通道 200“上次更改”时间戳会更新:
mds9513(config-if)# sh int po200 port-channel 200 is trunking Hardware is Fibre Channel Port WWN is xx:xx:xx:xx:xx:xx:xx:xx Admin port mode is auto, trunk mode is on snmp link state traps are enabled Port mode is TE Port vsan is 10 Speed is 4 Gbps Trunk vsans (admin allowed and active) (10) Trunk vsans (up) (10) Trunk vsans (isolated) () Member[1] : fc3/1 Interface last changed at Mon Jul 20 23:04:10 2015 ++++ Updated Last changed time.
Причина
这是设计的本意。
Разрешение
Cisco 确认,将接口添加到端口通道后,它将成为端口通道的一部分,并合并为一个聚合逻辑链路实体。因此,应在逻辑链路(端口通道)实体上检查“上次更改”时间戳,而不是在物理 FC 接口上检查。
各个端口摆动仅记录在“show logging log”输出中。
Затронутые продукты
Connectrix MDS-Series HardwareПродукты
ConnectrixСвойства статьи