EVT-TLMY-00001 Telemetry could not be sent to CloudIQ connectivity with Secure Remote Services failed

Сводка: Telemetry could not be sent to CloudIQ connectivity with Secure Remote Services failed.

Данная статья применяется к Данная статья не применяется к Эта статья не привязана к какому-либо конкретному продукту. В этой статье указаны не все версии продуктов.

Симптомы

Data Domain was found throwing below warning alerts:
Event Message:  Telemetry could not be sent to CloudIQ, %1.

This will repeat frequently as 20-30 min and would reappear even after clearing the alert.
This warning alert appears on Data Domain due to network issue on SRS/SCG Gateway server.
Some collection service would be down and cause the issue on SRS/SCG Gateway.
It is for unable to transmit message to the SRS/SCG Gateway.

SNMP must be restarted for the changes to take effect on DD.

# snmp show config
# snmp disable
# snmp enable


SNMP referenceData Domain: Common SNMP configuration and Issues causing Monitoring Services disabled in Integrated Backup Software or DPA


Причина

Network issue on SRS/SCG Gateway server.

Разрешение

Restart the services or SRS/SCG Gateway server.
If needed update the SRS/SCG version as well to the latest.

Дополнительная информация

Collab with Secure Remote Services team for further issue on SRS/SCG Gateway.

Затронутые продукты

Data Domain, PowerProtect Data Protection Hardware

Продукты

Secure Connect Gateway
Свойства статьи
Номер статьи: 000207011
Тип статьи: Solution
Последнее изменение: 12 Nov 2025
Версия:  7
Получите ответы на свои вопросы от других пользователей Dell
Услуги технической поддержки
Проверьте, распространяются ли на ваше устройство услуги технической поддержки.