PowerStore: Pre-Upgrade Heath Check Detects that Not All the SSDs are in a RAID Group

Сводка: The Pre-Upgrade Heath Check (PUHC) detects that not all the SSDs are in a RAID group when run before an upgrade.

Данная статья применяется к Данная статья не применяется к Эта статья не привязана к какому-либо конкретному продукту. В этой статье указаны не все версии продуктов.

Симптомы

The PUHC checks before an upgrade if all the SSDs are in a Dynamic Resiliency Engine (DRE) group (also known as a RAID Group).

The following messages may be displayed when run PUHC is run prior to a PowerStoreOS upgrade:

The RAID subsystem is not ready for OS upgrade to start on Node A. Check for any tier in a non-optimal state or remaining free capacity in the system at a low level. (raid_status_not_ready_failed_A)   

Or

At least one of the ssd is not ready to start upgrade. Please contact your service provider. (ssd_isd_not_ready_to_start_upgrade)

Screenshot where PUHC detects this issue: Screenshot where PUHC detects this issue 

 

screen shot of PUHC error details 

The following error codes may be raised:

0xE10010200007
0xE10010200008

Причина

The upgrade does not run properly if an SSD is not in a healthy DRE (RAID) group.

Разрешение

Contact Dell Technical Support to bring SSDs out of failure status. Mention this article ID for expedited handling.