Connectrix B-Series: Device Logging In as a Loopback

摘要: This article explains why a Connectrix B-Series switch port may detect an attached HBA or storage device as a loopback port and how to troubleshoot the condition.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

An HBA or storage device automatically configures as a loopback port on a Connectrix B-Series switch.

 

原因

This could be caused by the controller configuration on the HBA or storage device.

 

解决方案

Check whether the end device is configured for Fibre Channel Arbitrated Loop (FC-AL). Also check the integrity of the SFP and cable. Then reset the port as follows:

  • portcfgpersistentdisable
  • portcfgdefault
  • portcfgpersistentenable

If the status of the port is still loopback after performing the above, move the cable to a free port. If the issue follows the cable, it is likely an issue with the connected device. Further troubleshooting must be performed at that end.

 

受影响的产品

Connectrix B-Series Hardware

产品

Connectrix, Connectrix B-Series Hardware
文章属性
文章编号: 000053011
文章类型: Solution
上次修改时间: 28 7月 2026
版本:  4
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。