症状
分布式设备的虚拟卷状态在一个群集上显示服务状态为“running”,在另一个群集上显示服务状态为“inactive”,如下所示。
设备“service-status”在 cluster-1 上显示为“running”的示例:
VPlexcli:/clusters/cluster-1/virtual-volumes/device_problem_volume_vol> ll Name Value -------------------------- ---------------------------------------- block-count 104857920 block-size 4K cache-mode synchronous capacity 400G consistency-group Consistency_Group_x expandable true expandable-capacity 0B expansion-method storage-volume expansion-status - health-indications [] health-state ok locality distributed operational-status ok recoverpoint-protection-at [] recoverpoint-usage - scsi-release-delay 0 service-status Running <<<<< storage-array-family symmetrix storage-tier - supporting-device device_C1_problem_volume system-id device_ problem_volume_vol thin-capable true thin-enabled disabled volume-type virtual-volume vpd-id VPD83T3:6000144000000010604145145xxxxxx
设备“service-status”在 cluster-2 上显示为“inactive”的示例:
VPlexcli:/clusters/cluster-2/virtual-volumes/device_problem_volume_vol> ll Name Value -------------------------- ---------------------------------------- block-count 104857920 block-size 4K cache-mode synchronous capacity 400G consistency-group Consistency_Group_x expandable true expandable-capacity 0B expansion-method storage-volume expansion-status - health-indications [] health-state ok locality distributed operational-status ok recoverpoint-protection-at [] recoverpoint-usage - scsi-release-delay 0 service-status inactive <<<<< storage-array-family symmetrix storage-tier - supporting-device device_C2_problem_volume system-id device_ problem_volume_vol thin-capable true thin-enabled disabled volume-type virtual-volume vpd-id VPD83T3:6000144000000010604145145xxxxxx
虚拟卷的所有其他运行状况指标均良好。
原因
使用群集 1 和群集 2 上的“存储视图”导出卷。以下示例中 cluster-2 上显示的 “inactive” 状态源于以下事实:没有将前端端口分配给 cluster-2 上的存储视图,但在 cluster-1 的“storage-view”中声明 了 前端端口,如下所示:
显示存储视图中群集 1 上的“port-name-enabled-status”或“ports”行中存在前端端口的示例,但群集 2 未列出前端端口:
VPlexcli:/> ll /clusters/cluster-*/exports/storage-views/SV_problem_volume /clusters/cluster-1/exports/storage-views/SV_ problem_volume: Name Value ------------------------ ------------------------------------------------------------------------------ caw-enabled true controller-tag - initiators [A_host_HBA0, B_host_HBA1] operational-status ok port-name-enabled-status [P0000000047A0038A-A0-FC00,true,ok, P0000000047B00458-B0-FC01,true,ok] ports [P0000000047A0038A-A0-FC00, P0000000047B00458-B0-FC01] <<<<< virtual-volumes [(0,device_ problem_volume_vol,VPD83T3:6000144000000010604145145xxxxxx,400G)] write-same-16-enabled true xcopy-enabled true /clusters/cluster-2/exports/storage-views/SV_problem_volume: Name Value ------------------------ ------------------------------------------------------------------------------ caw-enabled true controller-tag - initiators [A_host_HBA0, B_host_HBA1] operational-status ok port-name-enabled-status [] ports [] <<<<< virtual-volumes [(0,device_ problem_volume_vol,VPD83T3:600014400000001060414514xxxxxx,400G)] write-same-16-enabled true xcopy-enabled true
解决方案
这是基于配置的问题,不是由于 VPLEX 上的故障或失灵造成的。
要将虚拟卷置于“正在运行”状态,请将前端端口添加到存储视图(对于导出的虚拟卷来说缺少这些端口)。
有关在存储视图中添加或移除前端端口的说明,请查阅 戴尔支持网站上提供的适用 GeoSynchrony 版本的《VPLEX 管理员指南》。
其他信息
此内容已翻译成不同的语言:
| https://downloads.dell.com/TranslatedPDF/AR-SA_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/DE_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/ES_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/ES-XL_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/FR_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/IT_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/JA_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/KO_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/NL_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/PT_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/PT-BR_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/RU_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/SV_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/ZH-CN_537392.pdf |
| https://downloads.dell.com/TranslatedPDF/ZH-TW_537392.pdf |
受影响的产品
VPLEX Series产品
VPLEX GeoSynchrony, VPLEX VS2, VPLEX VS6文章属性
文章编号: 000056157
文章类型: Solution
上次修改时间: 09 6月 2026
版本: 5
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。