PowerFlex: SDS panics due to memory allocation failures - mos_AllocPageAlignedOrPanic

摘要: SDS process can panic (or keep panicking continuously) due to memory allocation failures.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

Either insufficient memory can cause this problem on the SDS host (i.e. SVM memory assignment) or due to Operating System configuration.

The SDS process panics with the following backtrace:

01/12 22:26:55.091827 Panic in file /data/build/workspace/ScaleIO-SLES12-2/src/mos/usr/mos_utils.c, line 235, function mos_AllocPageAlignedOrPanic, PID 11191.Panic Expression pMem != ((void *)0) .
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(mosDbg_PanicPrepare+0x11d) [0x4f713d]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(mos_AllocPageAlignedOrPanic+0x2d) [0x4fa95e]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(stmp_Allocate+0x110) [0x49c063]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(phyToothMap_HardenIntern+0x37b) [0x46edcf]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(phyToothMap_HardenAll+0x39) [0x46f5a3]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(phyDev_HardenCombArr+0x34) [0x464a31]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(phyComb_ReadTooth+0x6a) [0x4b2b59]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(raidMigrate_Start+0x5f0) [0x4bb9e2]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133(raidSyncPool_StartJob+0x1cf) [0x489e7f]
/opt/emc/scaleio/sds/bin/sds-2.6.0.133() [0x50d008]

Depending on the OS settings, OOM (Out-of-memory) errors can be observed in the messages file.

 

Impact

This behavior can trigger a DATA_DEGRADED/DATA_FAILURE situation.

原因

Insufficient memory on the SDS host In the vSphere environment please checks if there is enough RAM assigned to an SVM and if it is reserved. If yes, check memory configuration at the OS level:

Check the sysctl kernel parameters for overcommit of memory:
File path /etc/sysctl.conf
 

# sysctl -a |grep commit
vm.overcommit_memory = 2 (default is 0)
vm.overcommit_ratio = 50 (default is 50)

 

解决方案

This is not a PowerFlex issue. PowerFlex is working as Designed.

 

To check and/or modify the vm.overcommit settings follow these steps:

1. Log in to the SDS using SSH as root

2. Run 

cat /etc/sysctl.conf | grep "vm.overcommit"


Ex.

[root@sds-node logs]# cat /etc/sysctl.conf | grep "vm.overcommit"
vm.overcommit_memory = 2
vm.overcommit_ratio = 50

3, Run the following commands

sed -i 's/vm\.overcommit_memory = .*/vm\.overcommit_memory = 2/g' /etc/sysctl.conf
sed -i 's/vm\.overcommit_ratio = .*/vm\.overcommit_ratio = 100/g' /etc/sysctl.conf
sysctl -p
Validation
[root@sds-node logs]# cat /etc/sysctl.conf | grep "vm.overcommit"
vm.overcommit_memory = 2
vm.overcommit_ratio = 100
Repeat these steps on all impacted SDSs in the environment to ensure that they are set to the recommended best practice settings.  You do not need to place the SDS into maintenance mode to perform this operation. 

 