DELL Unity:刷新 Unity 5.1.2 和 VNXe2 之间的复制远程连接将失败(用户可更正)

摘要: 在“刷新本地系统上的远程系统连接”步骤期间,刷新 Unity 5.1.2 和 VNXe2 之间的复制远程连接将失败。

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

错误代码;0x6500128
错误代码:0x100a - “Refresh remote system connections on local system (failed)”
日志错误显示:
"[
{"en-US":"The expression str is not supported. (Error Code:0x7d1312a)"}
]"

这发生在尝试刷新复制互连之前。
 
\spx\EMC\CEM\log\cemtracer_dataprotection.log
 
03 Mar 2022 19:50:27 - [RESTClient] ERROR - {0:1881678:506552869}[30175|1511|d83ffb40][handleError @ /c4_working/Unity_PullRequest_Build_Driver_Sles15_RTM_1.1/infrastructureproviders/components/RESTClient/src/RESTSession.cpp:1187] request https://10.8.1.137/api/types/replicationInterface/instances?fields=instanceId%2Cid%2CnasServer%2CipPort%2Chealth%2CinterfaceIpAddress%3A%3A%40str%28ipAddress%29%2CipProtocolVersion%2Cname failed: 131150122 {"error":{"errorCode":131150122,"httpStatusCode":422,"messages":[{"en-US":"The expression str is not supported. (Error Code:0x7d1312a)"}],"created":"2022-03-03T19:50:27.112Z"}} 03 Mar 2022 19:50:27 - [RESTClient] ERROR - {0:1881678:506690709}[30175|1511|d83ffb40][getInstances @ /c4_working/Unity_PullRequest_Build_Driver_Sles15_RTM_1.1/infrastructureproviders/components/RESTClient/src/RESTSession.cpp:797] Caught exception: /c4_working/Unity_PullRequest_Build_Driver_Sles15_RTM_1.1/infrastructureproviders/components/RESTClient/src/RESTSession.cpp:1213 code: 131150122, message: REST request failed: {"error":{"errorCode":131150122,"httpStatusCode":422,"messages":[{"en-US":"The expression str is not supported. (Error Code:0x7d1312a)"}],"created":"2022-03-03T19:50:27.112Z"}}

原因

这是由于 Unity OE 5.1 中引入的另一个问题的代码修复造成的。  它将 STR 函数添加到 REST 查询中。VNXe2 不支持 STR 函数。

解决方案

已在 Unity OE 5.2.0.0.5.173 及更高版本中修复。

受影响的产品

Dell EMC Unity, VNXe2 Series
文章属性
文章编号: 000197388
文章类型: Solution
上次修改时间: 13 5月 2026
版本:  6
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。