PowerStore: System Check detects unnecessary de-stages
摘要: The System Check detects if there are unnecessary de-stages, which may lead to excessive drive wear.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
If the System Check detects the excessive wear issue, the following error message is displayed: "Possible issue causing excessive wear on drives is detected. (KB#000220203)"
Screenshot of the PowerStore Manager:
When detected by the service script svc_health_check:
Screenshot of the PowerStore Manager:
When detected by the service script svc_health_check:
[...@ABCDEF-A ~]$ svc_health_check run -rhc dp_dedupe_destage_leak_check Name Location Status Description Datapath Dedup Destage Leak node_a Failed Possible issue causing excessive wear on drives is detected. (KB#000220203) Datapath Dedup Destage Leak node_b Failed Possible issue causing excessive wear on drives is detected. (KB#000220203) SUMMARY Status: Failed Passed: 0 Failed: 2 Total: 2
原因
The system check detects the issue of KB 000206257 PowerStore: NVMe SSD may wear faster due to increased write amplification.
The issue is resolved in 3.6 and later.
The issue is resolved in 3.6 and later.
解决方案
If the issue is detected, upgrade to 3.6 or later.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.
其他信息
KB 000192601 PowerStore: How to Check the Health of the Cluster Before Software Upgrade Using Pre-Upgrade Health Check and System Check.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks lists all the health checks in the Health Check thin package.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks lists all the health checks in the Health Check thin package.
受影响的产品
PowerStore文章属性
文章编号: 000220203
文章类型: Solution
上次修改时间: 14 6月 2025
版本: 3
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。