PowerStore: System Check detects unnecessary de-stages

摘要: The System Check detects if there are unnecessary de-stages, which may lead to excessive drive wear.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

If the System Check detects the excessive wear issue, the following error message is displayed: "Possible issue causing excessive wear on drives is detected. (KB#000220203)"

Screenshot of the PowerStore Manager:image.png

When detected by the service script svc_health_check:
[...@ABCDEF-A ~]$ svc_health_check run -rhc dp_dedupe_destage_leak_check
Name                               Location  Status     Description
Datapath Dedup Destage Leak        node_a    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
Datapath Dedup Destage Leak        node_b    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
 
 
SUMMARY Status: Failed
   Passed:      0
   Failed:      2
   Total:       2
 

原因

The system check detects the issue of KB 000206257 PowerStore: NVMe SSD may wear faster due to increased write amplification.

The issue is resolved in 3.6 and later.

解决方案

If the issue is detected, upgrade to 3.6 or later.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.

其他信息

受影响的产品

PowerStore
文章属性
文章编号: 000220203
文章类型: Solution
上次修改时间: 14 6月 2025
版本:  3
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。