摘要: This article explains why a Connectrix B-Series switch port may detect an attached HBA or storage device as a loopback port and how to troubleshoot the condition.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
An HBA or storage device automatically configures as a loopback port on a Connectrix B-Series switch.
原因
This could be caused by the controller configuration on the HBA or storage device.
解析度
Check whether the end device is configured for Fibre Channel Arbitrated Loop (FC-AL). Also check the integrity of the SFP and cable. Then reset the port as follows:
portcfgpersistentdisableportcfgdefaultportcfgpersistentenable
If the status of the port is still loopback after performing the above, move the cable to a free port. If the issue follows the cable, it is likely an issue with the connected device. Further troubleshooting must be performed at that end.