Isilon: Node does not provision in to existing Nodepool because wrong SSD was ordered

摘要: In this specific case, two new nodes would not provision in to the nodepool. The customer had a 16 node H500 cluster. The last two nodes installed have a single SSD drive with size 1.6T and not 3.2T as found with the other 14 nodes. ...

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

The first 14 nodes of the customer cluster were H500 nodes with a single 3.2 TB SSD drive. Customer received two new nodes with a single 1.6 TB SSD drive.
It is not possible to swap out the 1.6 TB drive for a new 3.2 TB drive. Isilon Nodes track the factory-installed hardware in special, hidden files, called "receipt" files or "PSI" files.
If the SSD drives are being used for L3 cache:  Adding a second 1.6 TB SSD would bring the two new nodes into the nodepool.
If the SSD drives are being used for "storage" (L3 Enabled = No): The size and count of the SSD drives must match for all nodes to be in the same nodepool.

原因

Two new nodes were joined to the cluster but were shown in the WEBUI as "unprovisioned."  Command-line queries show that new nodes were not in the expected nodepool.
 

MYCLUSTER-6# isi storage pool nodepools  list
ID   Name                      Nodes  Protection Policy  Manual 
----------------------------------------------------------------
1    h500_60tb_6.4tb-ssd_128gb 1      +2d:1n             No     
                               2                                
                               3                                
                               4                                
                               5                                
                               6                                
                               7                                
                               8                                
                               9                                
                               10                               
                               11                               
                               12                               
                               13                               
                               14                               
----------------------------------------------------------------
Total: 1


The new nodes - Nodes 15 and 16 - are not in the nodepool.

解析度

This is a Sales problem. In the first instance, the Sales or Account Team should be contacted in order to have the correct nodes shipped. If the nodes with the incorrect hardware were Joined to the cluster, the incorrect nodes must be Smartfailed out of the cluster. New nodes with the correct hardware can be Joined to the cluster.
Customers should contact the Sales team, quoting this KB if needed.