Connectrix MDS:IPStorage 介面因連接埠軟體故障而故障
摘要: IPStorage 介面因連接埠軟體故障而故障。
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
交換器會記錄以下錯誤訊息:
'show logging log file': 2016 Aug 24 10:57:17 SPAY-FCIP01 %ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface IPStorage1/1 is down (Port software failure) 2016 Aug 24 11:00:40 SPAY-FCIP01 %ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface IPStorage1/1 is down (Port software failure) 2016 Aug 24 11:06:48 SPAY-FCIP01 %ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface IPStorage1/1 is down (Port software failure) 2016 Aug 24 11:07:35 SPAY-FCIP01 %ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface IPStorage1/1 is down (Port software failure)
'show interface brief': switch: Switch-PR -------------------------------------------------------------------------------- Interface Status IP Address Speed MTU Port Channel -------------------------------------------------------------------------------- IPStorage1/1 swFailure 172.xx.xxx.xxx/24 10 Gbps 1500 -- switch: Switch-DR -------------------------------------------------------------------------------- Interface Status IP Address Speed MTU Port Channel -------------------------------------------------------------------------------- IPStorage1/1 up 10.xx.xxx.xx/30 10 Gbps 2300 --
原因
兩個交換器上的 MTU 不相同。此參數在兩端必須相同。
- 所有乙太網路連接埠的預設 IP 最大傳輸單元 (MTU) 訊框大小為 1500 位元組。
- 交換器「Switch-PR」上的 MTU 為 1500,對等交換器「Switch-DR」上的 MTU 為 2300
解析度
變更 MTU,使兩端具有相同的 MTU 值。
比如:
執行以下命令,將交換器 Switch-DR 上的 MTU 變更為 1500。
如果連接埠仍未連線,則必須將交換器重新開機。
比如:
執行以下命令,將交換器 Switch-DR 上的 MTU 變更為 1500。
configure terminal interface IPStorage1/1 switchport mtu 1500要恢復軟體故障,請使用以下隱藏命令重新載入受影響的 FCIP 引擎:
switch# ips reset module port
注意:此命令會中斷交換器上的所有 FCIP 通道。
如果連接埠仍未連線,則必須將交換器重新開機。
受影響的產品
Connectrix MDS-9250i產品
Connectrix MDS-9250i, Connectrix MDS-Series Hardware, Connectrix MDS-Series Software文章屬性
文章編號: 000064965
文章類型: Solution
上次修改時間: 08 10月 2025
版本: 3
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。