DSA-2019-124: Dell EMC PowerConnect Security Vulnerability

摘要: Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K firmware has been updated to address a vulnerability which may be potentially exploited to compromise the system.

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

影響

High

詳細資料

Dell PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks.

CVSS Base Score:7.2 (CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)

Dell PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks.

CVSS Base Score:7.2 (CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)

Dell Technologies 建議所有客戶不僅要參考 CVSS 基本分數,也要將可能會影響與特定安全漏洞相關之潛在嚴重性的所有相關暫時和環境分數納入考量。

受影響的產品與補救措施

Affected products:

The below Dell EMC PowerConnect models running firmware versions prior to 5.1.15.2: 

  • 8024
  • 7000
  • M6348
  • M6220
  • M8024
  • M8024-K

Remediation:

The following Dell EMC PowerConnect firmware release contains a resolution to the vulnerability:

  •     Dell EMC PowerConnect firmware version 5.1.15.2 and later.

Customers can download the latest firmware version at the support site for their respective model below:

  Dell EMC recommends all customers upgrade at the earliest opportunity. 
 

Affected products:

The below Dell EMC PowerConnect models running firmware versions prior to 5.1.15.2: 

  • 8024
  • 7000
  • M6348
  • M6220
  • M8024
  • M8024-K

Remediation:

The following Dell EMC PowerConnect firmware release contains a resolution to the vulnerability:

  •     Dell EMC PowerConnect firmware version 5.1.15.2 and later.

Customers can download the latest firmware version at the support site for their respective model below:

  Dell EMC recommends all customers upgrade at the earliest opportunity. 
 

感謝

Dell EMC would like to thank Daniel Cobb (@droctapus1) for reporting this vulnerability.