VxRail: Event Code: VXR008005 - A non-qualified external storage array is attached

摘要: This KB article discusses VxRail Event code: VXR008005 - A non-qualified external storage array is attached.

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

VxRail Event code: VXR008005 alarm is triggered when an external storage array that is not qualified by Dell is attached to one or more hosts in the cluster through a Fibre Channel (FC) cable with an FC switch, and one or more Logical Unit Numbers (LUNs) are assigned to the hosts.

原因

VxRail only provides FC connectivity, either with FC Host Bus Adapters (HBAs) bought with VxRail hardware, or FC HBAs plugged in by the customer. VxRail does not check or ensure FC HBA, FC fabric, or external storage array compatibility.

VxRail does not manage FC HBA firmware, FC switches, or external storage array lifecycle management, either. It is the customer's responsibility to ensure the compatibility for the whole FC path.

解析度

If customers are confident about compatibility, they could ignore this warning alarm.

For assistance troubleshooting the issue, contact Dell Technical Support or your Authorized Service Representative. Quote this knowledge base article ID by using the following option: Contact Technical Support | Dell US

其他資訊

This event code is introduced in versions 4.7.420 and 7.0.100.

文章屬性
文章編號: 000169438
文章類型: Solution
上次修改時間: 12 5月 2026
版本:  8
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。