PowerProtect DP Series Appliance: Security Warnings for PTAdmin Account
摘要: This article describes causes, and resolution for security warnings observed for the PTAdmin account in iDRAC.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
The iDRAC life-cycle log may show events indicating login failures or password changes for user "PTAdmin" or User ID 16. A corresponding email alert may be received from the ACM.
2022-07-09 19:45:46 27872 XXX0030 Successfully logged in using PTAdmin, from x.254.0.2 and H1. 2022-07-09 19:45:41 27870 XXX0030 Successfully logged in using PTAdmin, from x.254.0.2 and H2. 2022-07-09 19:45:47 27874 XXX1911 User ID 16 User Password has been changed. 2022-07-09 19:45:40 27869 XXX1912 User ID 16 User Access Right has been changed.
原因
The Dell PTAgent software agent running on the ESXi host creates and manages the PTAdmin user.
The agent software updates the password every 60 days.
Other users should not modify the password.
When the PTAgent is restarted, the password is updated.
The password may be changed when recovering from an error state.
解析度
This behavior is normal and requires no intervention.
If these messages occur with excessive frequency, reach out to Dell support for review.
受影響的產品
Integrated Data Protection Appliance Software產品
PowerProtect Data Protection Appliance, PowerProtect Data Protection Software, Integrated Data Protection Appliance Family文章屬性
文章編號: 000212219
文章類型: Solution
上次修改時間: 22 7月 2026
版本: 3
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。