Connectrix MDS:線路卡無法開機,並顯示錯誤「PORT-5-MODULE_BRINGUP_NOT_ALLOWED
摘要: 實際插入先前裝入 Director 插槽的線路卡無法開機。
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
插入先前已填入的 MDS Director 插槽時,線路卡無法開機。
當新線路卡的型號與原始線路卡的型號相同時,會顯示下列系統記錄訊息:
%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Speed group configuration is not supported. (0x4029018c)
如果新線路卡的型號與原始線路卡不同,則會顯示下列系統記錄訊息:
%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 10 to come up for reason: Speed change not allowed (0x4029007f)
在這兩種情況下,系統會記錄下列系統記錄順序:
%VMM-2-VMM_SERVICE_ERR: VDC1: Service SAP Port manager (high) for slot 8 returned error 0x402901ac (Module insertion failed) in if_bind sequence %IM-3-IM_RESP_ERROR: Component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND in vdc:1 returned error:Module insertion failed %IM-3-IM_SEQ_ERROR: Error (Module insertion failed) while communicating with component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND (for:RID_MODULE: 8) %MODULE-2-LCM_MODULE_INSERT_FAILURE_NEG_RSP: Slot-8 has failed to boot up because of service "Im SAP" due to module insertion failure
模組最終會進入 故障 狀態,如 show module command:
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------
1 34 1/10/40G IPS,2/4/8/10/16G FC Module DS-X9334-K9 failure
Mod Power-Status Reason
--- ------------ ---------------------------
1 failure Unknown. Issue show system reset mod ...
原因
思科互操作性問題
解析度
因應措施:
若要避免發生此問題,請執行以下命令: purge module x running-config 當插槽是空的時。
如果問題已發生,請備份組態,並執行下列會中斷的命令。
write erase write erase boot reload
已知已修復版本:
無
受影響的產品
Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9710-V2, Connectrix MDS-9718, Connectrix MDS-Series Hardware文章屬性
文章編號: 000219178
文章類型: Solution
上次修改時間: 16 4月 2025
版本: 3