Connectrix MDS:線路卡無法開機,並顯示錯誤「PORT-5-MODULE_BRINGUP_NOT_ALLOWED

摘要: 實際插入先前裝入 Director 插槽的線路卡無法開機。

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

插入先前已填入的 MDS Director 插槽時,線路卡無法開機。

當新線路卡的型號與原始線路卡的型號相同時,會顯示下列系統記錄訊息:

%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Speed group configuration is not supported. (0x4029018c)

如果新線路卡的型號與原始線路卡不同,則會顯示下列系統記錄訊息:

%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 10 to come up for reason: Speed change not allowed (0x4029007f)

在這兩種情況下,系統會記錄下列系統記錄順序:

%VMM-2-VMM_SERVICE_ERR: VDC1: Service SAP Port manager (high) for slot 8 returned error 0x402901ac (Module insertion failed) in if_bind sequence

%IM-3-IM_RESP_ERROR: Component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND in vdc:1 returned error:Module insertion failed

%IM-3-IM_SEQ_ERROR: Error (Module insertion failed) while communicating with component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND (for:RID_MODULE: 8)

%MODULE-2-LCM_MODULE_INSERT_FAILURE_NEG_RSP: Slot-8 has failed to boot up because of service "Im SAP" due to module insertion failure

模組最終會進入 故障 狀態,如 show module command: 


Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
1    34     1/10/40G IPS,2/4/8/10/16G FC Module DS-X9334-K9        failure

Mod  Power-Status  Reason
---  ------------  ---------------------------
1    failure        Unknown. Issue show system reset mod ...

原因

思科互操作性問題

解析度

因應措施:
若要避免發生此問題,請執行以下命令: purge module x running-config 當插槽是空的時。

如果問題已發生,請備份組態,並執行下列會中斷的命令。

write erase
write erase boot
reload

已知已修復版本:

受影響的產品

Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9710-V2, Connectrix MDS-9718, Connectrix MDS-Series Hardware
文章屬性
文章編號: 000219178
文章類型: Solution
上次修改時間: 16 4月 2025
版本:  3