VxRail: Two-Node Cluster Deployment Fails to Assign Storage Policy

摘要: The deployment cannot assign a storage policy because the VMkernel interface vmk0 carries an extra vSAN Witness tag; only the management network tag should be present, causing the failure. ...

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

During a two‑node VxRail cluster deployment the process cannot assign the storage policy to the virtual machine. The VxRail Manager reports that it cannot create the required three fault domains.

Symptoms observed:

  • Deployment stops with a failure to assign the storage policy.
  • Management network interface vmk0 shows an unexpected vSAN Witness tag.

原因

-There is vSAN Witness Tag enabled on the management Network as well.
- VMK0 should only have on Tag which is the Management Network:

Screenshot of vmk tagging 

解析度

  1. Run the command below to check for the tags associated with VMK0:
    esxcli network ip interface tag get -i vmk0
  2. Run the command below to remove the VSAN witness tag:
    esxcli network ip interface tag remove -i vmk0 -t VSANWITNESS
  3. Retry the configuration again now.
  4. If the issue remains, refresh the VMK0 connection and retry the configuration again:
    esxcli network ip interface set -e false -i vmk0
    esxcli network ip interface set -e true -i vmk0

受影響的產品

VxRail, VxRail Appliance Series, VxRail Software
文章屬性
文章編號: 000221852
文章類型: Solution
上次修改時間: 22 9月 2026
版本:  4
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。