PowerFlex: PM1733a/PM1735a Drives are missing in iDRAC - PDR5 or PR8

摘要: Dell PM1735a NVMe (Non-Volatile Memory Express) drive failing in PowerEdge servers

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

Dell PowerEdge based servers configured with Dell Samsung PM1735a may report drives as failed, offline, or missing in the iDRAC and operating system. This can occur on a system with an NVMe enabled PERC storage controller or NVMe direct configuration.
If there is a failure, the following error messages can be present in the LifeCycle Controller logs.

PDR5  - Disk arg1 in Backplane 1 in of RAID Controller in SL3 is removed
PDR1001 - Fault detected on drive arg1 in disk drive bay
CTL137 - iDRAC is unable to successfully communicate with the device PCIe SSD in Slot X in Bay Y
PR8 - Device not detected: Dell NVMe PCIe SSD Configuration Data(PCIe SSD in Slot X in Bay Y)

 

Disk model can be checked form iDRAC > Physical Disks 

原因

Dell Samsung PM1735a drives can assert due to an internal job interfering with a parity update operation.

解析度

Dell Technologies recommends updating the PM1733a/PM1735a drive firmware at the earliest available opportunity to avoid future occurrences of this error condition.

Dell Samsung PM1733a and PM1735a drives can both be updated using these new firmware versions
Once a drive has entered into a failed state, it is not possible to recover or update it.
 

 

Not Encrypted Devices

Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware

 

Self Encrypted Devices (SED)

Note: Instant Secure Erase (ISE) and Federal Information Processing Standards (FIPS) versions of the drive each require a different firmware package to update.

 

受影響的產品