Chassis Management Controller Version 5.1 for Dell PowerEdge M1000e RACADM Command Line Reference Guide

PDF

getsensorinfo

Description Displays the status for system sensors.

To run this subcommand, you must have the login user privilege.

Synopsis
  • racadm getsensorinfo
  • racadm getsensorinfo -c
Input -c — Compact output format.
Example
racadm getsensorinfo
<senType> <Num> <sensorName> <status> <reading> <units> <LC> <UC>
FanSpeed 1 Fan-1 OK 4768 rpm 2344 14500
FanSpeed 2 Fan-2 OK 4873 rpm 2344 14500
FanSpeed 3 Fan-3 OK 4832 rpm 2344 14500
FanSpeed 4 Fan-4 OK 4704 rpm 2344 14500
FanSpeed 5 Fan-5 OK 4833 rpm 2344 14500
FanSpeed 6 Fan-6 OK 4829 rpm 2344 14500
FanSpeed 7 Fan-7 OK 4719 rpm 2344 14500
FanSpeed 8 Fan-8 NOT OK 1 rpm 2344 14500
FanSpeed 9 Fan-9 OK 4815 rpm 2344 14500
Temp 1 Ambient_Temp OK 22 celcius N/A 40
<senType> <Num> <sensorName> <status> <health>
PWR 1 PS-1 Online OK
PWR 2 PS-2 Online OK
PWR 3 PS-3 Online OK
PWR 4 PS-4 Slot Empty N/A
PWR 5 PS-5 Failed OK
PWR 6 PS-6 Slot Empty N/A
<senType> <Num> <sensorName> <status>
Cable 1 IO-Cable OK
Cable 2 FPC-Cable OK