Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

OpenManage Integration for VMware vCenter Version 4.0 Compatibility Matrix

BIOS, iDRAC, Lifecycle Controller versions

The BIOS, iDRAC, and the Lifecycle Controller versions required to enable the features of OpenManage Integration for VMware vCenter are listed in this section.

Dell recommends you to use Server Update Utility (SUU), Repository Manager, or Lifecycle Controller's Platform to update your servers to one of the following base versions before using OMIVV:

Table 1. BIOS for Dell PowerEdge 11th generation serversThe following table specifies the compatible BIOS versions for the Dell PowerEdge 11th generation servers:
Server Minimum version
PowerEdge R210 1.8.2 or later
PowerEdge R210II 1.3.1 or later
PowerEdge R310 1.8.2 or later
PowerEdge R410 1.9.0 or later
PowerEdge R415 1.8.6 or later
PowerEdge R510 1.9.0 or later
PowerEdge R515 1.8.6 or later
PowerEdge R610 6.1.0 or later
PowerEdge R710 6.1.0 or later
PowerEdge R710 6.1.0 or later
PowerEdge R715 3.0.0 or later
PowerEdge R810 2.5.0 or later
PowerEdge R815 3.0.0 or later
PowerEdge R910 2.5.0 or later
PowerEdge M610 6.1.0 or later
PowerEdge M610x 6.1.0 or later
PowerEdge M710HD 5.0.1 or later
PowerEdge M910 2.5.0 or later
PowerEdge M915 2.6.0 or later
PowerEdge T110 II 1.8.2 or later
PowerEdge T310 1.8.2 or later
PowerEdge T410 1.9.0 or later
PowerEdge T610 6.1.0 or later
PowerEdge T710 6.1.0 or later
Table 2. BIOS for Dell PowerEdge 12th generation serversThe following table specifies the compatible BIOS versions for the Dell PowerEdge 12th generation servers:
Server Minimum version
T320 1.0.1 or later
T420 1.0.1 or later
T620 1.2.6 or later
M420 1.2.4 or later
M520 1.2.6 or later
M620 1.2.6 or later
M820 1.2.6 or later
R220 1.0.3 or later
R320 1.2.4 or later
R420 1.2.4 or later
R520 1.2.4 or later
R620 1.2.6 or later
R720 1.2.6 or later
R720xd 1.2.6 or later
R820 1.7.2 or later
R920 1.1.0 or later
Table 3. BIOS for Dell PowerEdge 13th generation serversThe following table specifies the compatible BIOS versions for the Dell PowerEdge 13th generation servers:
Server Minimum version
R630 1.0.4 or later
T630 1.0.4 or later
R730 1.0.4 or later
R730xd 1.0.4 or later
R430 1.0.2 or later
R530 1.0.2 or later
R830 1.0.2 or later
R930 1.0.2 or later
T130 1.0.2 or later
T330 1.0.2 or later
T430 1.0.2 or later
R230 1.0.2 or later
R330 1.0.2 or later
M630 1.0.0 or later
M830 1.0.0 or later
FC430 1.0.0 or later
FC630 1.0.0 or later
FC830 1.0.0 or later
Table 4. iDRAC and Lifecycle Controller for deploymentThe following table specifies the iDRAC and Lifecycle Controller versions for the Dell PowerEdge servers:
Generation Version
iDRAC Lifecycle Controller
Dell PowerEdge 11th generation servers 3.35 for Modular, 1.85 for Rack or Tower 1.5.2 or later
Dell PowerEdge 12th generation servers 1.00.0 or later 1.0.0.3017 or later
Dell PowerEdge 13th generation servers 2.30.30.30 or later 2.30.30.30 or later
Table 5. BIOS and iDRAC requirements for cloud serverThe following table specifies the BIOS and iDRAC requirements cloud servers:
Model BIOS iDRAC with Lifecycle Controller
C6320 1.0.2 2.30.30.30 or later
C4130 1.0.2 2.30.30.30 or later

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\