Dell Chassis Management Controller Version 3.0 for Dell EMC PowerEdge VRTX User's Guide

Setting Temperature Warning Threshold of the Enclosure Using RACADM

To set the minimum warning threshold of temperature probe in the enclosure, use racadm raid set tempprobes:TempSensor.Embedded.0:Enclosure.External.1-0:RAID.ChassisSlot.6-1 –p MinimumWarningThreshold <value> command.

To set the maximum warning threshold of temperature probe in the enclosure, use racadm raid set tempprobes:TempSensor.Embedded.0:Enclosure.External.1-0:RAID.ChassisSlot.6-1 –p MaximumWarningThreshold <value> command.

For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals.