Power | ||
---|---|---|
AC Power Supply (per power supply) | ||
Wattage | 350 W and 550 W | |
Heat dissipation NOTE: Heat dissipation is
calculated using the power supply wattage rating. |
1356 BTU/hr maximum (redundant, 350 W power supply) 1531 BTU/hr maximum (non-redundant, 350 W power supply) 2132 BTU/hr maximum (redundant, 550 W power supply) |
|
Voltage NOTE: This system is also
designed to be connected to IT power systems with a phase to phase
voltage not exceeding 230 V. |
100–240 V AC, autoranging, 50/60 Hz | |
Battery | ||
Coin-cell battery | 3 V CR2032 Lithium coin cell |
Physical | |||
---|---|---|---|
Height | 42.8 mm (1.68 inch) | ||
Width | |||
With rack latches | 482.4 mm (18.99 inch) | ||
Without rack latches | 434.0 mm (17.08 inch) | ||
Depth (excludes bezel) | 607.0 mm (23.9 inch) | ||
Weight (maximum) | 19.3 kg (42.55 lb) | ||
Weight (empty) | 16.33 kg (36 lb) |
Environmental | ||
---|---|---|
NOTE: For additional information
about environmental measurements for specific system configurations,
see dell.com/environmental_datasheets. |
||
Temperature | ||
Operating | Continuous operation: 10 °C to 35 °C
at 10% to 80% relative humidity (RH), with 26 °C max dew point. De-rate
maximum allowable dry bulb temperature at 1 °C/300 m above 900 m (1°F
per 550 ft). NOTE: For
information on supported expanded operating temperature range and
configurations, see support.dell.com/manuals. |
|
Storage | –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour | |
Relative humidity | ||
Operating | 20% to 80% (noncondensing) at a maximum wet bulb temperature of 29 °C (84.2 °F) | |
Storage | 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F) | |
Maximum vibration | ||
Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations) | |
Storage | 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested) | |
Maximum shock | ||
Operating | One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation | |
Storage | Six consecutively executed shock pulses
in the positive and negative x, y, and z axes (one pulse on each side
of the system) of 71 G for up to 2 ms Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 32 G faired square wave pulse with velocity change at 270 inches/second (685 centimeters/second) |
|
Altitude | ||
Operating | –15.2 m to 3048 m (–50 to 10,000 ft) NOTE: In compliance with the requirements of the official Chinese standards,
the operating altitude for systems shipping in China is in the range
of –15.2 m to 2000 m (–50 ft to 6560 ft). NOTE: For altitudes above
2950 ft, the maximum operating temperature is derated 1 ºF/550 ft. |
|
Storage | –15.2 m to 10,668 m (–50 ft to 35,000 ft) | |
Airborne Contaminant Level | ||
Class | G1 as defined by ISA-S71.04-1985 |