Integrated Dell Remote Access Controller 9 Version 3.30.30.30 User's Guide

Setting warning threshold for power consumption using web interface

  1. In the iDRAC Web interface, go to System > Overview > Present Power Reading and Thresholds.
  2. In the Present Power Reading and Thresholds section, click Edit Warning Threshold.
    The Edit Warning Threshold page is displayed.
  3. In the Warning Threshold column, enter the value in Watts or BTU/hr.
    The values must be lower than the Failure Threshold values. The values are rounded off to the nearest value that is divisible by 14. If you enter Watts, the system automatically calculates and displays the BTU/hr value. Similarly, if you enter BTU/hr, the value for Watts is displayed.
  4. Click Save. The values are configured.