getdcinfo

Description

Displays general I/O module and daughter card configuration information. Only the CMC controls daughtercards.

To use this subcommand, you must have the CMC Login User privilege.

  • NOTE: Fabric verification for server DCs is performed only when the chassis is turned on. When the chassis is on stand-by power, iDRACs on the server modules remain turned off and thus are unable to report the server's DC fabric type. The DC fabric type may not be reported in the CMC user interface until iDRAC on the server is turned on.

Synopsis

racadm getdcinfo

Input

-n — Displays the model names for the daughter cards in servers.

Example

The following example is for a system with multi-slot servers.

racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : PCIe
Group C I/O Type : PCIe
<
                                                IO#>
                                             
<
                                                Type>
                                             
<
                                                State>
                                             
<
                                                Role>
                                             
switch-1
Gigabit Ethernet
OK
Master
<
                                                Server#>
                                             
<
                                                Presence>
                                             
<
                                                DC1 Type>
                                             
<
                                                DC1 State>
                                             
<
                                                DC2 Type>
                                             
<
                                                DC2 State>
                                             
server-1
Present
PCIe
OK
PCIe
OK
server-2
Not Present
None
N/A
None
N/A
server-3
Present
PCIe
OK
None
N/A
server-4
Not Present
None
N/A
None
N/A
getdcinfo -n
<
                                                Server#>
                                             
<
                                                Presence>
                                             
<
                                                DC1 Model Name>
                                             
<
                                                DC2 Model Name>
                                             
server-1
Present
None
None
server-2
Not Present
None
None
server-3
Not Present
None
None
server-4
Present
None
Broadcom M5708t