Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Dell Chassis Management Controller Version 3.10 for PowerEdge VRTX RACADM CLI Guide

PDF

get psus

Table 1. Details of get psus. The following table provides the details of get psus attribute:

Description

Displays the status and attributes of the Power Supply Unit (PSU) in the storage enclosure that are connected to chassis

  • NOTE: To use this subcommand, you must have the CMC Login User privilege.

Synopsis

racadm raid get psus -o -p Status
                                                racadm raid get psus -o
                                             

Input

  • -o — The -o is used to display the fault-tolerant status of a enclosure.

Example

racadm raid get psus -o -p Status
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                
                                             
racadm raid get psus -o
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 0
                                                PartNumber                       = 0NFCG1A01
                                                PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 1
                                                PartNumber                       = 0NFCG1A01
                                                PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 0
                                                PartNumber                       = 0D1YWRA00
                                                PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 1
                                                PartNumber                       = 0GV5NHA00
                                                
                                             

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"