Dell PowerEdge R730 Owner's Manual

uSATA SSD indicator codes

Figure 1. uSATA SSD indicators
This figure shows uSATA SSD indicators.
  1. uSATA SSD activity indicator
  2. uSATA SSD status indicator
  3. uSATA SSD
NOTE: If the SSD is in the Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does not function and remains off.
Table 1. Drive status indicator codesThe following table contains the drive LED indicator pattern with the drive status.
Drive-status indicator pattern Condition
Flashes green twice per secondIdentifying drive or preparing for removal.
OffDrive ready for insertion or removal.
NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on. Drives are not ready for insertion or removal during this time.
Flashes green, amber, and turns offPredicted drive failure
Flashes amber four times per secondDrive failed
Steady greenDrive online
Flashes green for three seconds, amber for three seconds, and turns off after six secondsRebuild aborted

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"