Dell Chassis Management Controller Version 3.0 for Dell EMC PowerEdge VRTX User's Guide

Conversion of External Shared PERC 8 card Non-High Availability to High Availability Mode using Web Interface

Dell PowerEdge VRTX chassis must have 2 External Shared PERC 8 cards in PCI slot 5 and PCI slot 6.

Workflow

  1. Power down chassis. Disconnect all SAS cables from External Shared PERC 8 cards to MD12x0 enclosures.
  2. Power Up chassis.
  3. Login to CMC web interface and navigate to the Storage→ Controllers→ Troubleshooting and enable Fault tolerance from the drop-down menu for External Shared PERC 8 card in slot 5, click Apply and select disable for slot 6, and then click Apply.

  4. Resetting both the PERCs may take two minutes to reflect in HA mode.
  5. Power down chassis and connect the enclosures in HA Mode.
  6. Power Up chassis.
  7. External Shared PERC 8 card is in HighAvailabiltiy Mode and navigate to Storage→ Troubleshooting→ Setup Troubleshooting to view the HA status.