Articles
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 1552 shown
1552 out of 1552 shown
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: June 17, 2026
ID: 000205512
Step-by-step guidance to replace with customer certificates for Dell VxRail environments. vSphere provides security by using certificates to encrypt communications, authenticate services, and sign tokens. (Customer Correctable)
Updated: May 15, 2026
ID: 000019755
Event code: VXR508PWR8528
This event code indicates "Unable to set Max Power Conservation Mode because the Server Based Power Management mode is enabled."
Updated: June 19, 2026
ID: 000011433
Event code: VXR508PWR8514
This event code indicates "Unable to perform chassis power action due to insufficient privileges."
Updated: June 19, 2026
ID: 000011432
Event code: VXR508PWR8570
This event code indicates "Unable to communicate to the iDRAC, when trying to power cycle the server <slot number>."
Updated: June 19, 2026
ID: 000011431
The Intelligent Orchestration Engine (IOE) may fail to establish connectivity with one or more VxRail system components. A common cause of this issue is customer network security configurations blocking SSH traffic (TCP port 22). IOE requires SSH access to securely communicate with VxRail nodes and management components to perform orchestration and automation tasks.
Updated: June 19, 2026
ID: 000440702
This event indicates that "Memory RAID redundancy is lost. Check memory device at locations <location>."
Updated: June 19, 2026
ID: 000008900
Error code MYSTIC500MEM1016 and VXR500MEM1016 indicate "Memory device at location <location> is not installed correctly."
Updated: June 19, 2026
ID: 000008881
VxRM cluster upgrade pre-check to make sure cluster not having self-signed certificate when vLCM enabled.
Updated: June 19, 2026
ID: 000479066
Event code: VXR508PWR8552
This event code indicates "Chassis Management Controller is unable to turn on <component name>-<component id> because of insufficient power."
Updated: June 18, 2026
ID: 000011429
Event code: VXR508PWR8576
This event code indicates "Unable to turn on the Sleeve or Sled <slot number> after a virtual reseat operation."
Updated: June 18, 2026
ID: 000011427
Event code: VXR508PWR8509
This event code indicates "Unable to change the server power priority because Server Based Power Management mode is enabled."
Updated: June 18, 2026
ID: 000011426
Event code: VXR508PWR8562
This event code indicates "Unable to power on the server <server number> before power on timer expired."
Updated: June 18, 2026
ID: 000011425
Event code: VXR508PWR8595
This event code indicates "Chassis Management Controller is unable to turn on server <slot id> due to insufficient power for the <chassis component name>."
Updated: June 18, 2026
ID: 000011423
Event code: VXR508RDU0023
This event code indicates "Unable to determine the redundancy status of the fans."
Updated: June 18, 2026
ID: 000011422
Event code: VXR508PWR8511
This event code indicates "Unable to set the CHASSIS_POWER_button_disable chassis power property."
Updated: June 18, 2026
ID: 000011421
Event code: VXR508PWR8566
This event code indicates "Unable to turn off the Server <server number> before the Power Off timer expired."
Updated: June 18, 2026
ID: 000011418
Event Code: VXR508PWR8670
This event code indicates "Unable to turn on server<slot ID> because the required power <power level> AC Watts exceeds the subsystem Connector Limit <power limit> AC Watts for IO modules, Blowers, and Servers."
Updated: June 18, 2026
ID: 000011417
Event code: VXR508STOR015
This event code indicates "Maximum virtual disks allowed for this controller has been reached."
Updated: June 18, 2026
ID: 000011416
Event code: VXR508STOR041
This event code indicates "Invalid value for AttributeName <attribute name>"
Updated: June 18, 2026
ID: 000011415
Event code: VXR508STOR013
This event code indicates "One or more storage device(s) are not in a state where the operation can be completed."
Updated: June 18, 2026
ID: 000011414
Event code: VXR508PWR8656
This event code indicates "Chassis Management Controller (CMC) is unable to turn on the component <component name>-<slot number> because of insufficient power."
Updated: June 18, 2026
ID: 000011413
VxVerify on VxRail Manager checks the IP for each node for port 9090 or 39090.
Updated: June 18, 2026
ID: 000193194
When enabling the vSphere Lifecycle Manager feature on the cluster, it fails with an error 'Compliance scan task failed'.
Updated: June 18, 2026
ID: 000193256
For a new node running on VxRail versions from 8.0.320 to 8.0.361, during host first boot, the VxRail manager virtual machine is powered on and configured with Skylake CPU mode. If the cluster Enhanced vMotion Compatibility (EVC) mode is lower than Skylake, then adding the new node to the cluster reports CPU incompatible error.
Updated: June 18, 2026
ID: 000388870
VXR0140A1 alarm triggers when vSAN (vSAN) cluster storage space exceeds configured thresholds (vSAN 7.0 Update 2 onward). Check and reduce vSAN datastore usage per VMware KB 71003.
Updated: June 17, 2026
ID: 000182229
Event code: VXR508RDU0003
This event code indicates "Fan redundancy is degraded."
Updated: June 17, 2026
ID: 000011727
Event code: VXR508TMP0108
This event code indicates "The memory module <number> temperature is greater than the upper warning threshold."
Updated: June 17, 2026
ID: 000011726
Event code: VXR508PWR1007
This event code indicates "The system performance degraded because power exceeds capacity."
Updated: June 17, 2026
ID: 000011725
The node upgrade fails when upgrading from ESXi 8.x to ESXi 9.x, if any existing or custom-uploaded drivers are incompatible with ESXi 9.
Updated: June 17, 2026
ID: 000404333