PowerEdge R630 image

PowerEdge R630

PowerEdge R630

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 341 shown
341 out of 341 shown

This article explains how to create and import an iDRAC certificate.
Updated:  May 28, 2026 ID: 000120158

This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Updated:  May 25, 2026 ID: 000136481

How to Identify the physical slot number in iDRAC based off the device name in vSphere/VSAN.
Updated:  June 01, 2026 ID: 000179543

This article provides information about exporting the Tech Support Report (TSR) / SupportAssist Collection, including the Operating System, Application Data, and the RAID controller log. This is done using the integrated Dell Remote Access Controller (iDRAC) command-line interface (CLI) of Dell PowerEdge servers generations 12, 13, and 14.
Updated:  June 01, 2026 ID: 000120100

This document answers questions about SupportAssist Enterprise.
Updated:  June 01, 2026 ID: 000060848

The drive will assert due to a log full condition after the first power cycle when it reaches 70000 Power On Hours (POH). The drive will not process read or write commands once in this state.
Updated:  May 25, 2026 ID: 000217034

PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Updated:  May 24, 2026 ID: 000415896

PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
Updated:  May 24, 2026 ID: 000396285

Fans reporting FAN0000/FAN0001 errors (RPM below warning or critical) should be removed and swapped to another connector; if the error follows the fan, replace it.
Updated:  May 24, 2026 ID: 000391086

Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated:  May 24, 2026 ID: 000381662

Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
Updated:  May 24, 2026 ID: 000379421

The article provides the solution to the firmware update errors for ConnectX-4 LX NICs SWB 76DNG version 14.32.21.02 & ConnectX-5 dual port SWB 1GF8G version 16.35.40.30.
Updated:  May 24, 2026 ID: 000378312

This article provides information about the LIC008 error seen when importing the IDRAC License.
Updated:  May 23, 2026 ID: 000353269

This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Updated:  May 23, 2026 ID: 000349619

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
Updated:  May 23, 2026 ID: 000314166

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated:  May 22, 2026 ID: 000246018

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Updated:  May 21, 2026 ID: 000237298

In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated:  May 21, 2026 ID: 000233949

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Updated:  May 21, 2026 ID: 000226989

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Updated:  May 20, 2026 ID: 000223671