This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: August 18, 2026
ID: 000205512
PowerFlex R650 R750 nodes with Complex Programmable Logic Device (CPLD) firmware 1.0.7 or earlier may is unavailable at POST when BIOS 1.8.2 and iDRAC 6.00.30.202 are installed, triggering iDRAC PowerFlex alerts.
Updated: August 04, 2026
ID: 000205925
Running command svm status connection is showing both CloudLink nodes as Inaccessible due to blocked port UDP 1194.
Updated: August 19, 2026
ID: 000384973
This article shows the PowerFlex release matrix, and guidance on how to correlate the various packages.
Updated: August 19, 2026
ID: 000461757
Software Defined Storage (SDS) on a server panics, showing “data degraded”, losing Client (SDC) volume access and O. The panic is due to a kernel futex race‑condition issue, causing unavailability.
Updated: August 19, 2026
ID: 000281636
The system reports repeated SDS disconnection and possibly I/O errors appearing on the clients.
Updated: August 19, 2026
ID: 000058476
ASR0000 appears when the hardware watchdog timer expires after iDRAC Service Module communication ends, caused by loss of iDRAC‑host OS connectivity, such as a powered‑off host or a degraded module.
Updated: August 19, 2026
ID: 000219431
This knowledge article describes how to set up a Bring Your Own (BYO) Hypervisor for the PowerFlex Management Platform (PFMP) in a Rack or Appliance Deployment use case with PFMP versions 4.6.x, 4.8.x, and 5.x.x.
Updated: August 18, 2026
ID: 000339284
SDC is failing to start scini service with insmod error: "could not insert module ../scini.ko: Required key not available."
UEFI Secure Boot is enabled or the kernel parameter module.sig_enforce is set on the SDC host. This configuration is not supported for PowerFlex deployment.
Updated: August 18, 2026
ID: 000227045
During maintenance operations on the PowerFlex Management Cluster (PFMC), the SDS node fails to exit and remains in Protected Maintenance Mode (PMM), as MDM rejects the request and returns the error SDS_MAINTENANCE_MODE_EXIT_FAILED with the message "The wrong maintenance mode type was chosen for this SDS".
Updated: August 18, 2026
ID: 000501252
PowerFlex Rack remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: August 18, 2026
ID: 000498657
PowerFlex Manager 4.x may show false alerts—CONFIGURED_SPARE_CAPACITY_SMALLER_THAN_LARGEST_FAULT_UNIT, STORAGE_POOL_UNBALANCED, NOT_ENOUGH_FAULT_UNITS_IN_SP due to a known software issue pending fix.
Updated: August 17, 2026
ID: 000279687
This article explains the meaning of Dial Home Symptom code SIO02.04.0000009 and how to troubleshoot it.
Updated: August 17, 2026
ID: 000381561
Scli login fails with "Error: Failed to connect to MDM 127.0.0.1:8611"
Scenario
Updated: August 17, 2026
ID: 000203269
SupportAssist is connected; however AIOps (formerly known as CloudIQ (CIQ)) shows the 'Last Contacted' time as days or weeks ago.
Updated: August 17, 2026
ID: 000399850
This article explain how to replace a failed drive in a deployed node. PowerFlex Manager supports the replacement of SSD and NVMe drives for PowerFlex storage-only nodes and hyperconverged nodes.
Updated: August 17, 2026
ID: 000382343
This article explains the procedure to perform a clean Shut Down or Startup of a PowerFlex system running in ESXi or Two Tier Environment.
Updated: August 17, 2026
ID: 000021739
This article contains the initial steps to take on all PowerFlex performance-based issues when observing performance degradation, low Input Output Operations Per Second (IOPs), low MB per sec, or high latency.
Updated: August 17, 2026
ID: 000220627
This article explains how to Calculate Spare Capacity
Updated: August 17, 2026
ID: 000065593
This article explains the calculation for storage pool free capacity in PowerFlex.
Updated: August 17, 2026
ID: 000195170
There is a security vulnerability in the log4j files that are contained on both the PowerFlex Gateway and Presentation Server. This article describes the steps to take to work around the issue.
Updated: August 17, 2026
ID: 000194498
How to get the Firmware version and other details of any device on a Dell PowerEdge server using racadm.
Updated: August 17, 2026
ID: 000023762
vMotion between ESXi hosts fails due to configuration mismatch of VHV setting.
Updated: August 17, 2026
ID: 000032908
This article explains how to configure "Certificate Chain of Trust" required for scli when using custom signed PowerFlex Manager Platform (PFMP) SSL certificates.
Updated: August 17, 2026
ID: 000239564
This article explains how to reboot different node types for PowerFlex systems.
Updated: August 17, 2026
ID: 000491367
iDRAC logs show MEM7114 critical memory events that can be false‑positive DIMM errors. The root cause is a BIOS firmware defect that misreports memory faults, particularly when C‑States are enabled.
Updated: August 16, 2026
ID: 000474769
The PowerFlex Manager appliance is showing space alerts for the /var/log partition.
Updated: August 14, 2026
ID: 000194791
This article explains how to troubleshoot Oscillating counters failure.
Updated: August 14, 2026
ID: 000012246
Container Storage Modules (CSM) Container Storage Interface (CSI) Driver for PowerFlex pods are stuck in CrashLoopBackOff state with error "could not find given NAS server by name."
Updated: August 14, 2026
ID: 000288040
This article explains how to troubleshoot the alert PFX00102.0000206) The disk space diagnostic failed.
Updated: August 14, 2026
ID: 000446673