This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: August 10, 2026
ID: 000205512
PowerVault ME5 reports an invalid firmware bundle on the controller. Power down and ensure that the SAS cables are connected in the right order per the deployment guide. The correct firmware is applied once the attached enclosures, then the ME5 enclosure are powered on.
Updated: August 10, 2026
ID: 000202472
Using PowerVault Manager an administrator will not see the ability to delete an unmapped and undiscovered initiator. Use the command line interface (CLI) instead.
Updated: August 10, 2026
ID: 000202287
ME5 Series Administrator's Guide and ME5 Series Storage System CLI Reference Guide do no reference permitted character limits for the Email notification sender password.
Updated: August 10, 2026
ID: 000203942
Administrators using SNMP v3 with PowerVault ME4 or ME5 Arrays may have applications that require the SNMP Engine ID to accept SNMP traps.
Updated: August 10, 2026
ID: 000204172
When upgrading a PowerVault ME5 series array to the latest ME5.1.1.0.5 build from ME5.1.0.1.0 the firmware upgrade will report it completes, however, does not activate. Workaround this by temporarily disabling partner firmware update (PFU).
Updated: August 10, 2026
ID: 000207484
PowerVault ME5 administrators may experience secure encrypted drives (SED) report an "FDE disk failure" after a reboot/power cycle or drive firmware update. This error causes the drive to be unusable and the array to be faulted. Storage controller restarts are needed to recover.
Updated: August 10, 2026
ID: 000217608
Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated: August 10, 2026
ID: 000222201
If a disk does not belong to an active disk group, if it should fail, an alert is not triggered.
Updated: August 10, 2026
ID: 000355553
This article outlines the standard workflow for adding expansion enclosures to the Dell PowerVault ME5, and ME52 series. It includes preparation steps, cabling requirements, enclosure detection, and post‑installation validation.
Updated: July 31, 2026
ID: 000426573
This article is intended for storage administrators who use Dell PowerVault ME4/ME5 arrays. It explains how to collect the right evidence, perform first‑pass checks, and identify common causes when hosts lose access to mapped volumes. Where deeper host operating system or switch configuration is required, consult the documentation from the operating system or switch vendor after completing the array‑side validation steps.
Updated: July 31, 2026
ID: 000426581
This article is to help verify Host‑to‑Volume Path Redundancy on PowerVault ME5 and ME52 series storage (SAS/iSCSI/FC). This covers where to check for path redundancy in the PowerVault Manager, what to expect per protocol, and how to verify MPIO on the host OS.
Updated: July 31, 2026
ID: 000426592
This article outlines the basic workflow in PowerVault Manager for creating a new volume or modifying an existing volume on a Dell PowerVault ME5 Storage. It covers assigning a pool, configuring volume settings, and mapping the volume to a host group or initiator.
Updated: July 31, 2026
ID: 000426595
This article summarizes the key differences between Linear and Virtual pools on PowerVault ME5 and ME52 storage. This also outlines considerations when selecting Disk Group (RAID) types such as RAID 1, RAID 10, RAID 5, RAID 6, and ADAPT.
For full recommendations, refer to the Dell PowerVault ME5 Storage Best Practices whitepaper.
Updated: July 31, 2026
ID: 000426601
This article provides an overview of ME5/ME52 expansion enclosures. This includes what they are, the types of alerts/faults that may be seen, and where to check health and status in the management interface. It also highlights common causes (power, hardware, and SAS cabling) and when to engage Dell Technical Support.
Updated: July 31, 2026
ID: 000426630
Dell PowerVault ME5 Storage remediation is available for multiple vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: July 30, 2026
ID: 000492468
Disk drives replaced under warranty may not be recognized when the disk drive in carrier (DDIC) interposer board does not line up with the drive slot connector in the ME4084/ME484 drawer or alternatively in some instances where the drive carrier latch is not secured properly causing the carrier to open when the drawer is closed. Follow the video guidance below to correctly remove, assemble, and insert the drive carrier.
Updated: July 30, 2026
ID: 000327933
This article provides a structured troubleshooting guide for customers who are unable to access the Dell PowerVault Manager web interface on ME5 Series storage arrays. There are multiple distinct causes for this symptom. Work through each section in order to identify and resolve your specific issue.
Updated: July 27, 2026
ID: 000486343
As part of a maintenance schedule, Dell recommends PowerVault ME administrators upgrade controller module firmware. These updates either add new features or resolve issues that affect availability or existing program features. For dual controller configurations this is a non disruptive update. Single controller configurations require an extended maintenance window as connected hosts must be shutdown.
Updated: July 13, 2026
ID: 000120120
SupportAssist must be enabled to send configuration and diagnostic information from a PowerVault ME5 Series storage system to technical support. Depending on your service contract, SupportAssist also automates support request creation for issues detected on the storage system.
Updated: July 07, 2026
ID: 000485953
Dell AIOps (formerly CloudIQ) is a cloud-based application that provides simple, proactive monitoring and troubleshooting of your Dell IT infrastructure including integration with VMware. It leverages machine learning to proactively monitor and measure the overall health of servers, storage, and switches through intelligent, comprehensive, and predictive analytics. Dell AIOps is available at no additional charge for Dell products covered with a valid ProSupport (or higher) contract.
Updated: June 29, 2026
ID: 000022224
This article describes how to find the serial number, product ID, or Product Serial Number Tag (PSNT) that is required to open a service request or support case for Dell Storage and Data Protection hardware products.
Updated: June 05, 2026
ID: 000021638
A ghost snapshot space appears (show snapshot-space) due to shared page‑count underflow causing incorrect reporting. The issue is addressed in firmware version (ME5.1.2.1.1), but pools created before the fix still show the issue; it is only cosmetic and requires no cleanup.
Updated: May 24, 2026
ID: 000438630
On Dell ME5 (ME50XX) and ME52 (ME52XX) platforms, creating more than ten schedules using Graphical User Interface (UI) fails; the 11th schedule creation returns an error. Affected firmware Versions ME5.1.2.1.5 (ME50XX) and ME5.2.0.0.2 (ME52XX)
Updated: May 24, 2026
ID: 000402153
When a PowerVault ME5 storage array is connected using an HBA465e adapter on Windows Server 2022 or 2025, it is not possible to add shared cluster disks.
Updated: May 23, 2026
ID: 000343322
This article discusses an issue where excessive network scanning on an iSCSI network caused system instability, including core crashes and unresponsive storage nodes. The root cause was identified as security scans flooding the iSCSI network, leading to resource exhaustion. The recommended resolution is to isolate iSCSI traffic from general network scans and follow best practices for secure iSCSI deployment.
Updated: May 23, 2026
ID: 000321701
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Updated: May 23, 2026
ID: 000311902
Administrators are unable to change default management IP address, subnet mask, and gateway on single controller using PowerVault Manager. Use the PowerVault command-line interface (CLI) to make the changes.
Updated: May 22, 2026
ID: 000197927
Creating a linear RAID array using the ME5 user interface, selecting all available disks may result in the Sub Groups not being populated correctly. This issue occurs across all RAID levels.
Updated: May 22, 2026
ID: 000280682
ME5 directly connected Initiators show the redundancy warning icon in the UI after updating to +ME5.1.2.1.0.
Updated: May 22, 2026
ID: 000264759