This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Updated:  May 23, 2026 ID: 000349619

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  May 23, 2026 ID: 000368482

Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Updated:  May 23, 2026 ID: 000333712

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

Dell Enterprise NVMe solid state drives may be leveraged as a substitute for Dell Data Center NVMe solid state drives.
Updated:  May 23, 2026 ID: 000315161

Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Updated:  May 23, 2026 ID: 000311902

Some Dell PowerEdge 16th Generation (16G) servers may exhibit a 0V reading for Central Processing Unit (CPU) Voltage Regulator sensors within the Integrated Dell Remote Access Controller 9 (iDRAC9) user interfaces.
Updated:  May 23, 2026 ID: 000309893

The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
Updated:  May 23, 2026 ID: 000308774

During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
Updated:  May 22, 2026 ID: 000278171

Performing a "yum update" check for Red Hat Enterprise Linux or SuSE Linux for Enterprise Servers updates may fail due to improper iDRAC RPM in the Dell YUM repository on linux.dell.com.
Updated:  May 22, 2026 ID: 000262378

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

DSU and SUU may not inventory any server components due to a crash caused in the invcol.exe module. Inventory Collector 24.09 and newer is no longer fully compatible with Windows Server 2016.
Updated:  May 22, 2026 ID: 000251806

CPUs can be perceived to be hot while server is idle.
Updated:  May 22, 2026 ID: 000250878

Various Dell enterprise products behave unexpectedly if IPMI is intentionally disabled from communicating between the operating system and iDRAC. This can be done by disabling the "In-band Management Interface" setting in BIOS System Security settings.
Updated:  May 22, 2026 ID: 000247770

The HBA355i with Seagate 8 TB SAS hard drive fails to boot to Windows Server 2022 after a cold boot.
Updated:  May 22, 2026 ID: 000245194

iDRAC Service Module (iSM) 5.4 and older versions fail to upload SupportAssist collections back to Dell. A "handshake API" error occurs. This upload feature has been deprecated due to the receiving servers at Dell had been decommissioned.
Updated:  May 21, 2026 ID: 000240336

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Updated:  May 21, 2026 ID: 000237298

When OpenManage Server Administrator (OMSA) is installed, an Event ID 7043 may be in the Windows System event log when the OS is shut down or restarted. It does not impede the shutdown process, and the event is only seen after the OS has been restarted.
Updated:  May 21, 2026 ID: 000237050

PowerEdge servers with Emulex Fiber Channel (FC) driver version 12.01.12 may fail driver installation under Windows Defender Application Control (WDAC) Enforced Mode on Windows Server.
Updated:  May 21, 2026 ID: 000236792

PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
Updated:  May 21, 2026 ID: 000236776

Attempts to update the Broadcom NetXtreme 5719 and 5720 Network Interface Card (NIC) using the .bin file with sudo in Linux results in an 'Inventory Collection Failure' error.
Updated:  May 21, 2026 ID: 000228045

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

After installing the Windows Server 2022 Software RAID driver during installation, the Micron 7500 drive does not immediately appear. Wait approximately 20-30 s and press the Refresh button more than once for it to become visible.
Updated:  May 21, 2026 ID: 000227822

Following the initial setup, the Intel Infrastructure Processing Unit (IPU) is unable to ping networks beyond its local network.
Updated:  May 21, 2026 ID: 000227435

Multiple SKHynix NVMe (PS1010) drives in the same server experienced PCIe link training failures during the deployment phase, resulting in the drives entering read-only mode.
Updated:  May 21, 2026 ID: 000227423

Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Updated:  May 21, 2026 ID: 000227227

If the Intel Infrastructure Processing Unit (IPU) is rebooted through the Infrastructure Management Controller (IMC), the entire server reboots.
Updated:  May 21, 2026 ID: 000226967

This is a new attribute that is seen in Server Configuration Profile exports. This attribute cannot be edited.
Updated:  May 21, 2026 ID: 000226963

This is seen when using direct attached storage with an Emulex LPe35002-M2-D and Red Hat Enterprise Linux, the server fails to boot.
Updated:  May 21, 2026 ID: 000226962