VxRail Software

VxRail Software

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 1388 shown
1388 out of 1388 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  May 11, 2026 ID: 000205512

The dockr_ver health check found that running docker images are not up to date with expected versions or missing.
Updated:  May 11, 2026 ID: 000189813

Event code: VXR500PST0133 This event code indicates "DMA controller failed."
Updated:  May 11, 2026 ID: 000013509

Event code: VXR500PDR13 This event code indicates "<physical disk> rebuild has failed."
Updated:  May 11, 2026 ID: 000013508

Event code: VXR500PST0136 This event code indicates "Programmable interval timer error."
Updated:  May 11, 2026 ID: 000013507

Event code: VXR500PDR51 This event code indicates "Hot spare <physical disk> SMART polling has failed.<args>"
Updated:  May 11, 2026 ID: 000013506

Running VxVerify health checks on VxRail versions since 7.0.010 requires VxRM root permissions to run all tests.
Updated:  May 11, 2026 ID: 000191504

Event code: VXR500PDR62 This event code indicates "The rebuild failed due to errors on the target <physical disk>."
Updated:  May 11, 2026 ID: 000013505

VxRail: Event Code: VXR500PDR73 This event code indicates "Copyback failed from <physical disk> to <physical disk>."
Updated:  May 11, 2026 ID: 000013504

Event code: VXR500PDR88 This event code indicates "Power state change failed on <PD Name>. (from <state> to <state>)"
Updated:  May 11, 2026 ID: 000013503

Event code: VXR500PST0141 This event code indicates "QuickPath Interconnect (QPI) fatal error."
Updated:  May 11, 2026 ID: 000013502

Event code: VXR500PDR44 This event code indicates "The clear operation on <physical disk> failed."
Updated:  May 11, 2026 ID: 000013501

Event code: VXR500PDR47 This event code indicates "A block on <physical disk> was punctured by the controller."
Updated:  May 11, 2026 ID: 000013500

Event code: VXR500PDR57 This event code indicates "Bad block table on <physical disk> is full. Unable to log block <logical block address >."
Updated:  May 11, 2026 ID: 000013499

VxRail: Event Code: VXR500PDR115 This event code indicates "The <PCIe solid state device name> is in read-only mode."
Updated:  May 11, 2026 ID: 000013498

VxRail: vCenter machine ID mismatch
Updated:  May 11, 2026 ID: 000455730

If the VxRail cluster has been upgraded from version 4.5.x to 7.0.240 or later, users must upgrade to newer releases and enable vSphere Lifecycle Management (vLCM).
Updated:  May 11, 2026 ID: 000190895

This article provides information about how to collect the VxRail Manager log bundle on VxRail version 4.7.x and 7.x, 8.x, or using command line.
Updated:  May 11, 2026 ID: 000190671

One or more VxRail Manager checks returns event code 1 or 2, for the dblogs test, representing a warning or fail, respectively. These must be investigated prior to upgrading the cluster.
Updated:  May 11, 2026 ID: 000190593

A diagnostic warning event occurred in the memory device.
Updated:  May 11, 2026 ID: 000184533

One or more memory errors have occurred during the Double Data Rate (DDR) memory channel initialization on the memory slot.
Updated:  May 11, 2026 ID: 000184534

Unable to use the system memory because the DIMMs are populated in an unsupported (configuration) manner.
Updated:  May 11, 2026 ID: 000184535

This is an iDRAC internal warning, indicating the Fibre Channel (FC) controller port link is down.
Updated:  May 11, 2026 ID: 000184758

Dell VxRail: event VXR508MEM6114 A diagnostic warning event occurred in the memory device at <location>. Contact your service provider for assistance in replacing the device. (Extended ID: <code>).
Updated:  May 11, 2026 ID: 000189212

VxRail appliance dials home to Dell EMC with event code VXR104205, indicating that VxRail Manager I2E desired configuration update operation failed.
Updated:  May 11, 2026 ID: 000197176

Event VXR508PR39 is reported after replacing the PERC card.
Updated:  May 11, 2026 ID: 000206256

Event VXR508STOR5001 is reported when an internal error in the storage library.
Updated:  May 11, 2026 ID: 000206259

A power‑off occurs when the inlet temperature exceeds the critical limit because the alert action is configured to shut down; the temperature condition itself does not trigger an automatic shutdown.
Updated:  May 11, 2026 ID: 000181231

Support new iDRAC events monitor: SEKM075. Event VXR508SEKM075 iDRAC is unable to switch from Local Key Management (iLKM) to Secure Enterprise Key Manager (SEKM)
Updated:  May 11, 2026 ID: 000190286

iDRAC Service Module (iSM) versions 4.0.1 and earlier for VMware ESXi may stop functioning and the dcism service stop if the core hostd service of the ESXi host was recently restarted.
Updated:  May 11, 2026 ID: 000190265