OEMR XR4510c image

OEMR XR4510c

OEMR XR4510c

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 153 shown
153 out of 153 shown

Learn how to create and export a SupportAssist Collection using iDRAC9 and iDRAC10 on Dell devices. Resolve technical issues with this step-by-step guide.
Updated:  December 08, 2025 ID: 000126308

Understand and troubleshoot PowerEdge hard disk drives, RAID, PowerEdge RAID Controller, and other storage hardware such as cables, backplane, so forth.
Updated:  December 03, 2025 ID: 000110444

This article provides information about how to boot past the Driver Health Manager Screen.
Updated:  December 23, 2025 ID: 000148089

Storage components may not be displayed, or the status may appear as Unknown after upgrading iDRAC9 firmware to version 7.20.60.50 or 7.20.70.50.
Updated:  December 12, 2025 ID: 000388426

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  December 11, 2025 ID: 000368482

If the SYSVOL share is absent from every domain controller (DC) in an Active Directory (AD) domain, AD management consoles may give an error like this: "An Active Directory domain controller (AD DC) for the domain <domain> could not be contacted." If Distributed File System Replication (DFSR) is used to replicate SYSVOL data, the issue appears difficult to resolve. An authoritative sync of DFSR cannot be performed without the ADSI Edit console. Fortunately, the issue can be resolved by modifying the registry on the DC with the authoritative copy of SYSVOL. A different registry modification is then performed on the other DCs.
Updated:  December 10, 2025 ID: 000198564

This article explains what a predictive drive failure (error code PDR16) means, why it occurs, and provides step-by-step instructions to troubleshoot and resolve the issue. It covers recommended actions such as backing up data, updating firmware, and replacing the disk if necessary to ensure storage health and prevent data loss.
Updated:  December 09, 2025 ID: 000126418

This article provides the recommended steps to help troubleshoot memory-related events on Dell PowerEdge servers.
Updated:  December 08, 2025 ID: 000304931

This article explains how to use iDRAC Direct to manage your PowerEdge server.
Updated:  December 04, 2025 ID: 000130077

This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers, how physical drive LED indicators provide quick visual diagnostics, and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
Updated:  December 04, 2025 ID: 000143247

This page explains the difference between drivers and firmware and how to update them on Dell PowerEdge Servers using different methods.
Updated:  December 02, 2025 ID: 000128194

The PowerEdge embedded LifeCycle Controller provides a simplified method for installation of supported Windows Server and Linux server operating systems with the OS Deployment feature. This article explains how to use the iDRAC LifeCycle Controller to install a supported operating system on most Dell PowerEdge servers. Step-by-step instructions and OS installation videos for Windows Server, Ubuntu Server LTS, SUSE Linux Enterprise Server, or Red Hat Enterprise Linux installation with LifeCycle Controller
Updated:  December 02, 2025 ID: 000130160

This article explains the difference between a reset and a Power Drain.
Updated:  December 02, 2025 ID: 000175625

This article explains how to create a Virtual Disk using the System Settings menu.
Updated:  December 01, 2025 ID: 000178269

Correctable and uncorrectable memory errors on PowerEdge Server with DDR4 and changes to troubleshooting steps
Updated:  November 25, 2025 ID: 000053203

This article is a step-by-step guide on how to replace a hard drive.
Updated:  November 14, 2025 ID: 000143539

This article describes how to gather the necessary log files to troubleshoot a vSphere Tanzu issue.
Updated:  November 12, 2025 ID: 000187022

Find answers and resources to get started or do more from your MyService360 dashboard with enterprise services data analytics and visualizations.
Updated:  November 10, 2025 ID: 000124666

When running the nvidia-smi command, you may encounter a driver error stating that "nvidia-smi has failed because it could not communicate with the NVIDIA driver.
Updated:  November 08, 2025 ID: 000252982

Dell iDRAC9 and iDRAC10 remediations are available for an arbitrary file export vulnerability that could be exploited by malicious users to compromise the affected system.
Updated:  November 06, 2025 ID: 000384516

This article explains how some Dell server platforms offer the optional security bezel with dust filter. The air filter bezel can be configured as Countdown Mode or Active Sensing Mode. After a certain period of lifetime, the IDRAC may report alert events and require the dust filter to be replaced.
Updated:  October 23, 2025 ID: 000217749

This article provides guidance for the Dell System Update (DSU).
Updated:  October 21, 2025 ID: 000130590

The firmware of PowerEdge server hard drives is a critical component in the server system. Regularly updating and maintaining this firmware is essential for server performance, security, and compatibility. Hard drive firmware updates can often fix known hardware faults and issues, address identified vulnerabilities and security problems, and potentially introduce new features, improvements, and enhancements.
Updated:  October 16, 2025 ID: 000226155

Dell XR4510C customers may report the iDRAC failed path does not fail over to other Lan On Motherboard (LOM) ports as expected.
Updated:  October 15, 2025 ID: 000208220

Dell iDRAC9 remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated:  September 30, 2025 ID: 000299628

Dell PowerEdge Server BIOS and iDRAC9 remediation is available for an Information Disclosure Vulnerability that could be exploited by malicious users to compromise the affected system.
Updated:  September 23, 2025 ID: 000370138

This article explains how to test the configured iDRAC email alerts settings.
Updated:  September 19, 2025 ID: 000203083

Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Updated:  September 17, 2025 ID: 000221846

Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Updated:  September 15, 2025 ID: 000333712

This article guides user through resolving link option issues available with this integrated LOM. This LOM is typically shipped with XR4000 chassis nodes and used in Telco, Mixed IP, and Azure Local (AX, MC) nodes like 4520C/4510C compute sleds.
Updated:  September 12, 2025 ID: 000353158