VxFlex Ready Node

VxFlex Ready Node

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 606 shown
606 out of 606 shown

This article provides links to PowerFlex software documentation.
Updated:  May 13, 2026 ID: 000307994

Dell PowerFlex remediation is available for the Apache Log4j Remote Code Execution Vulnerability that may be exploited by malicious users to compromise the affected system. Dell recommends implementing this remediation as soon as possible in light of the critical severity of the vulnerability.
Updated:  May 12, 2026 ID: 000194548

After following NDU flow and switching to 1_node MDM cluster, upgrading Secondary/TB MDMs and trying to put the back into the cluster, MDM throws an error.
Updated:  May 15, 2026 ID: 000203063

Upgrade will not start/finish the Finalize step, since the MDM is shown in an upgrade state in progress.
Updated:  May 15, 2026 ID: 000203061

When trying to create and map a volume to a Compute Node in OpenStack the operation is taking much more time (comparing to the other nodes) and the client is logging errors against the newly created device.
Updated:  May 15, 2026 ID: 000203060

Network connectivity issues cause Secondary MDM/s status to become Not synchronized.
Updated:  May 15, 2026 ID: 000203059

There is only one SDC that is having issues w/ performance.
Updated:  May 15, 2026 ID: 000203058

SDS reports sockets closed without any network events or evidence of networking issues.
Updated:  May 15, 2026 ID: 000203040

Errors are present whenever rebooting the SDC. IO times out from PowerFlex Gateway.
Updated:  May 15, 2026 ID: 000203037

Issue Description vSphere ESXi hosts hang and become inaccessible randomly after experiencing high latency within the datastores.
Updated:  May 15, 2026 ID: 000203027

Applications that are using PowerFlex volumes are reporting corruption when RMcache is enabled.
Updated:  May 15, 2026 ID: 000202877

In PowerFlex Manager 4.0, performing a Linux Compute Only deployment using a SLES 15 SP3 ISO gets stuck during the OS installation phase.
Updated:  May 15, 2026 ID: 000202410

Multiple SDS nodes may intermittently panic with a NO_RESOURCES assertion in spef_SynchronizeExtentDataWithIoCommitPhaseCk during high internal SPEF resource utilization.
Updated:  May 15, 2026 ID: 000465101

The customer is using the SDC monitoring pod (also called the sdc-monitor sidecar) and noticed an excessive amount of CPU is being used by it.
Updated:  May 15, 2026 ID: 000202226

Using PowerFlex Manager Deployment or Upgrade will fail in Diskless nodes due to the backplane. When performing deployments on diskless Compute Only (CO) nodes, if the backplane shows as non-compliant PFxM attempts to upgrade and it Fails.
Updated:  May 14, 2026 ID: 000200302

This article explains using the Boot Optimized Storage Solution - S2 (BOSS-S2) configuration utility to import a foreign virtual disk, a feature only when the controller detects a foreign disk.
Updated:  May 14, 2026 ID: 000249178

The guide explains converting a hard drive to non‑RAID by iDRAC, then claiming it for a PowerFlex Virtual Storage Area Network (VSAN) cluster and assigning cache or capacity roles.
Updated:  May 14, 2026 ID: 000248864

The user is checking performance using FIO (also seen with vdbench) and reports high latency during a rebuild.
Updated:  May 14, 2026 ID: 000244398

This article explain how to fix the restore operation failure when password is not encoded as mentioned in the admin guide
Updated:  May 14, 2026 ID: 000464562

The ScaleIO Data Server (SDS) panics at startup, producing stack traces and causing a single‑point‑of‑failure state; a Security-Enhanced Linux (SELinux) rule set is suspected, on version 3.5.1.1.
Updated:  May 14, 2026 ID: 000244393

PowerFlex upgrade from 3.6.0.6 to 4.5.2 fails, logs show “Failed to fork wrapper” and “Get Installed Components command was not successful” on nodes, caused by low memory and vCPU resources for SVMs.
Updated:  May 14, 2026 ID: 000244324

Storage‑Only Resource Group (RG) deployment fails with missing MDM IPs, connection timeouts and ARP errors; the cause is unconfigured port channels required by Partial Network Automation (PNA).
Updated:  May 14, 2026 ID: 000244319

Upgrade is blocked because a decommissioned vCenter remains in a compute‑only resource group on PFxM 3.6, preventing PowerFlex Management Platform from complying with the intelligent catalog.
Updated:  May 14, 2026 ID: 000242480

The Collects Logs feature collects the logs from all the system nodes although only a few were selected.
Updated:  May 14, 2026 ID: 000242474

Top PowerFlex Software and Hardware Dial Home Alerts; PowerFlex
Updated:  May 13, 2026 ID: 000184617

This article explains the step by step procedure to restore PFMP from a backup file
Updated:  May 13, 2026 ID: 000464566

Memory errors and CMCI storm entries in logs cause load, SDS stalls and decoupling; a failing Dual In-line memory module (DIMM) triggers interrupts, EDAC CMCI rate exceeds threshold, causing storm.
Updated:  May 13, 2026 ID: 000197735

This KB explains how to perform the WSFC conversion at a high-level. It also covers converting an Oracle RAC environment from RDMs to shared VMDKs on NVMe/TCP, even though Oracle RAC does not require SCSI3‑PR. Oracle RAC can run on an SDC‑based VMFS datastore, but because PowerFlex does not support Clustered VMDK on SDC‑based VMFS, SCSI3‑PR‑dependent applications cannot use that configuration. Oracle RAC explanations are also high-level.
Updated:  May 13, 2026 ID: 000417124

The customer is using PowerFlex SDR replication to test failover but the destination volume gets mounted "RO" in the multipath -ll output on the Oracle Linux server.
Updated:  May 13, 2026 ID: 000241854

PowerFlex 3.x UI is inaccessible, receive a 404 error when trying to open it. PowerFlex 3.x is reachable from the CLI.
Updated:  May 13, 2026 ID: 000233376