Leveraging the 'Reboot Required' filter and selecting all items in this filtered view results in the 'make compliant' job applying all non-compliant firmware components. An unexpected reboot of the target is seen as components that do require a restart are deployed to the target. The issue is only seen if selecting all objects and using the 'Reboot Required' filter. All other filters work as designed.
Updated:  May 22, 2026 ID: 000270340

Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated:  May 22, 2026 ID: 000246018

Users attempting to exit Enhanced Pre-Boot System Assessment (ePSA) diagnostics may encounter a system stop upon selecting the Exit option.
Updated:  May 22, 2026 ID: 000291042

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

CPUs can be perceived to be hot while server is idle.
Updated:  May 22, 2026 ID: 000250878

NVIDIA L-series GPUs may fall offline during runtime operations when running vGPU Grid 17.2 drivers.
Updated:  May 22, 2026 ID: 000250524

Performance drops after power supply unit (PSU) cable removal and does not recover upon reconnection, despite the A/B Grid Redundant policy being active in iDRAC10.
Updated:  May 22, 2026 ID: 000247062

Racadm diagnostics "-m 2" switch returns express diagnostics results only.
Updated:  May 22, 2026 ID: 000246053

Inband updates to Open Server Manager (OSM) with .bin DUP results in a watchdog soft lockup error. Update is successful.
Updated:  May 22, 2026 ID: 000244474

An incorrect slot type s reported under PCIe slot 7, reported as "OCP3Small" in iDRAC10 UI.
Updated:  May 22, 2026 ID: 000243237

Dell Update Package (DUP) can randomly fail in Red Hat Enterprise Linux (RHEL) or Ubuntu.
Updated:  May 22, 2026 ID: 000242250

The Lifecycle Controller logs reports SPDM0001 and SPDM0003 warning messages after every iDRAC reset.
Updated:  May 21, 2026 ID: 000242100

USB device latency using an external USB Hub connected to the front or back USB ports on PowerEdge R7725, R6725 systems
Updated:  May 21, 2026 ID: 000242069

Observing system stop responding or Purple Screen Of Death (PSOD) during ESXi 8.0 U3 installation,
Updated:  May 21, 2026 ID: 000241608

Seagate Summit SAS/SATA drives report medium errors or sense key 3/11 on PowerEdge and PowerVault systems due to a firmware issue causing weak writes to a drive sector.
Updated:  May 21, 2026 ID: 000239838

The BIOS setting changes may not appear in iDRAC if configured using the F11 Boot Manager on Dell PowerEdge 16G and 17G platforms.
Updated:  May 21, 2026 ID: 000238951

In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated:  May 21, 2026 ID: 000233949

OpenManage Enterprise integration for VMware vCenter may fail to Unmanage hosts with error "UNMANAGE_REMOVE_MEL_FAILURE"
Updated:  May 21, 2026 ID: 000233873

When a PS1010 or PS1030 NVMe SSD is installed, a PSOD may occur during production or gathering Operating System (OS) logs.
Updated:  May 21, 2026 ID: 000228837

OpenManage Enterprise version 4.1 entitlements feature will no longer work after October 2024 due to the decommissioning of legacy OAUTH APIs. Also, the standalone Dell License Manager application is end-of-life.
Updated:  May 21, 2026 ID: 000228401

When editing a deployment template the 'Edit Components' screen is stuck with the 'Loading' animation. Also, when editing a compliance template the 'Template Details' screen is blank.
Updated:  May 21, 2026 ID: 000228133

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

Connection Status shows disconnected for all devices in OpenManage Enterprise Services (OMES) plugin 4.1.0 under the Site Health tab - Managed Devices page.
Updated:  May 21, 2026 ID: 000227514

Multiple SKHynix NVMe (PS1010) drives in the same server experienced PCIe link training failures during the deployment phase, resulting in the drives entering read-only mode.
Updated:  May 21, 2026 ID: 000227423

Viewing the VLAN details of a deployment template's network settings list devices that are not associated to the template.
Updated:  May 21, 2026 ID: 000227227

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.