This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Updated:  May 25, 2026 ID: 000136481

Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Updated:  May 23, 2026 ID: 000333712

This is a general troubleshooting guide to help identifying if there is a problem with a physical disk in vSAN Clusters.
Updated:  May 29, 2026 ID: 000209262

The below article is a workaround mechanism to recover PowerEdge systems from critical log entry "SWC5008 Unable to access Front LED Panel because of a hardware error condition" for a few versions of the iDRAC.
Updated:  May 25, 2026 ID: 000205597

PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Updated:  May 24, 2026 ID: 000415896

Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated:  May 24, 2026 ID: 000381662

This article explains Dell guidelines on company administrator assignment.
Updated:  May 24, 2026 ID: 000379388

This article explains how to assign an Initial Company Administrator.
Updated:  May 23, 2026 ID: 000374134

This article explains how to promote Company Administrators.
Updated:  May 23, 2026 ID: 000374126

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  May 23, 2026 ID: 000368482

Dell Micron 9550 E3.S NVMe Drive Activity-Led light turns off for a few seconds.
Updated:  May 23, 2026 ID: 000309831

BIOS setting for Collaborative Processor Performance Control (CPPC) will remain disabled after attempting to enable it.
Updated:  May 22, 2026 ID: 000293675

Customers may notice that the rear iDRAC system ID button LED on some specific platforms becomes dim or turns off.
Updated:  May 22, 2026 ID: 000281224

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

CPUs can be perceived to be hot while server is idle.
Updated:  May 22, 2026 ID: 000250878

When a PS1010 or PS1030 NVMe SSD is installed, a PSOD may occur during production or gathering Operating System (OS) logs.
Updated:  May 21, 2026 ID: 000228837

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

Updating 16G PowerEdge Server BIOS may result in Secure Boot database updates.
Updated:  May 21, 2026 ID: 000226055

This is a firmware catalog which contains validated and certified firmware stack for selected Dell VMware vSAN Ready Nodes based on Dell customized ESXi 8.X branch Images.
Updated:  May 21, 2026 ID: 000225254

This is a firmware catalog which contains validated and certified firmware stack for selected Dell VMware vSAN Ready Nodes based on Dell customized ESXi 7.x branch Images.
Updated:  May 21, 2026 ID: 000225253

This is a firmware catalog which contains validated and certified firmware stack for selected Dell VMware vSAN Ready Nodes based on Dell customized ESXi 6.x branch-based Dell customized images.
Updated:  May 21, 2026 ID: 000225252

Dell Intel E810-C adapters do not support disabling the Virtual Machine Device Queue (VMDQ) loopback feature using "Intnetcli" tool.
Updated:  May 20, 2026 ID: 000223462

Certain PCIe Slots are Gen4 only. A change in the Basic Input Output System (BIOS) has resolved an incorrect reporting in Peripheral Component Interconnect Express (PCIe) capabilities on Gen4 slots. This is not a functional change. The change is cosmetic in nature only.
Updated:  May 20, 2026 ID: 000223307

CPU enumeration change is noticed after BIOS update on 16G Dell PowerEdge AMD Servers.
Updated:  May 19, 2026 ID: 000221896

After an update to 7.00.00.00 or higher, the iDRAC9 web server may become inaccessible where the user has uploaded a custom or CA signed web certificate.
Updated:  May 19, 2026 ID: 000220891

The iDRAC is unable to connect to a Server Message Block (SMB) share when the optional "SMB3 share encryption" is enabled.
Updated:  May 19, 2026 ID: 000219260

Dell SAS SSD models SS530 and SS540, when used as a VMware vSAN cache tier, show accelerated write endurance loss.
Updated:  May 19, 2026 ID: 000218401

This article describes what can happen while collecting SupportAssist logs using iDRAC9 UI. The operation may result in an error, or incomplete logs may be collected.
Updated:  May 17, 2026 ID: 000211904