This article provides PowerEdge server troubleshooting for No Power, No POST, No Boot and No Video issues. This includes blade, rack, and tower servers.
Updated: January 05, 2026
ID: 000152161
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: December 22, 2025
ID: 000205512
After upgrading the PowerFlex Management Platform from 4.0.0-161 to hotfix 4.0.0.1-169, the Resource Group Compliance Report shows no software components in the PowerFlex Manager UI.
Updated: January 09, 2026
ID: 000203532
PowerFlex Manager Platform (PFMP) crashes after restarting network services using "systemctl restart network."
Updated: January 09, 2026
ID: 000202162
When deploying a Storage-Only Resource Group on PowerFlex 5.x, the deployment wizard fails at IP reservation with error IDENTITYPOOLMANAGER.3004. The root cause is IP pools sized only for the storage nodes, without accounting for the additional MDM virtual IPs required by the deployment.
Updated: January 08, 2026
ID: 000412601
PowerFlex After the Motherboard is replaced, the node shows R740xd not VxFlex-R740xd in iDRAC.
Updated: January 08, 2026
ID: 000081547
Unable to run ScaleIO command, error: "MDM failed command. Status: Invalid session Login and try again."
Updated: January 08, 2026
ID: 000065938
The OS does not recognize a disk after adding it back into a server.
Updated: January 08, 2026
ID: 000058655
This article provides links to several Dell Community pages.
Updated: January 07, 2026
ID: 000127879
ElasticSearch Data corrupted or locked is commonly due to storage being full.
/var is where Elasticsearch data is stored.
Updated: January 07, 2026
ID: 000184668
All the masking view information is visible in SYMCLI. The customer is unable to see the masking view information for all local arrays. Within Unisphere, none of the array masking view details are visible.
Updated: January 06, 2026
ID: 000061535
SDS devices are missing data after reboot.
Updated: January 06, 2026
ID: 000211253
PowerFlex Upgrade Customer Preparation Guide
Updated: January 06, 2026
ID: 000340894
This article provides quick links to Dell PowerFlex for AWS and Dell PowerFlex for Microsoft Azure technical documentation.
Updated: January 05, 2026
ID: 000376743
SVMs would not Turn on after exiting maintenance mode.
Updated: January 05, 2026
ID: 000035615
This article describes the steps to troubleshoot a ScaleIO Cinder installation for OpenStack.
Updated: January 03, 2026
ID: 000008827
An alert is raised when a Disk Group (DG) enters a dual degraded capacity fault tolerance state, indicating that the system is at risk of data unavailability if another failure occurs.
Updated: January 03, 2026
ID: 000365825
An alert is raised when the Rebalance or Rebuild operation has been manually disabled for Device Groups (DG) in a Protection Domain (PD). This is typically done for maintenance or diagnostic purposes and should be re-enabled once the task is complete.
Updated: January 03, 2026
ID: 000365795
An alert is raised when an error is reported on a device.
Updated: January 03, 2026
ID: 000365773
Use this procedure to verify and upgrade the CPLD firmware version on PowerFlex nodes. PowerFlex Manager does not verify or upgrade CPLD.
Updated: January 03, 2026
ID: 000315068
An LDAP-enabled user gets a "no role assigned to user" error when making API calls.
Updated: January 03, 2026
ID: 000280795
After a successful PowerFlex Management Platform (PFMP) upgrade, the PowerFlex Gateway (GW) fails to proceed with the upgrade.
Updated: January 03, 2026
ID: 000274983
During PowerFlex management Platform (PFMP) deployment, one or more MVM's fail to deploy using the wizard with the following
error "HttpNfcLeaseState.error."
Updated: January 03, 2026
ID: 000264728
Sometimes support or customers must locate the Storage Devices from vSphere in PowerFlex. The Presentation Server shows the last eight digits when filtering the volumes by "VTree ID;" however, these digits might be the same for several volumes. The recommendation is to compare the last 16 digits of the eui in vSphere Client with the Volume ID shown in the CLI of the Primary MDM.
Updated: January 03, 2026
ID: 000264404
PowerFlex 4.X: Unable to deploy PowerFlex Storage Cluster. Error "Failed Bootstrap operation failed"
PowerFlex 4.x: Unable to deploy PowerFlex Storage Cluster. Error "Failed Bootstrap operation failed"
Updated: January 03, 2026
ID: 000262080
PowerFlex Manager is failing to complete a SO Deployment RG when performing the 'zypper update' task.
Updated: January 03, 2026
ID: 000262033
This article explains the detailed steps for how to rename the gateway after deployment
Updated: January 03, 2026
ID: 000262027
This article explains an issue where the keycloak-0 pod reports a health check failure due to database connectivity problems caused by an incorrect DNS configuration. This issue impacts authentication services managed by keycloak
Updated: January 03, 2026
ID: 000261288
PowerFlex Manager: RKE2 upgrade fails repeatedly due to "405 Not Allowed" error while creating the upgrade payload
During the PowerFlex Management Platform (PFMP) upgrade, the process fails repeatedly, looping at the point of creating the upgrade payload folder in the http-share. The failure occurs with an HTTP 405 Not Allowed error.
Updated: January 03, 2026
ID: 000261179
iDRAC password cannot be changed through the PowerFlex Management Platform (PFMP) web UI when using custom SSL certificates.
Updated: January 03, 2026
ID: 000258783