Articles
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 1381 shown
1381 out of 1381 shown
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: May 11, 2026
ID: 000205512
The dockr_ver health check found that running docker images are not up to date with expected versions or missing.
Updated: May 11, 2026
ID: 000189813
Event code: VXR500PST0141
This event code indicates "QuickPath Interconnect (QPI) fatal error."
Updated: May 11, 2026
ID: 000013502
Event code: VXR500PDR44
This event code indicates "The clear operation on <physical disk> failed."
Updated: May 11, 2026
ID: 000013501
Event code: VXR500PDR47
This event code indicates "A block on <physical disk> was punctured by the controller."
Updated: May 11, 2026
ID: 000013500
Event code: VXR500PDR57
This event code indicates "Bad block table on <physical disk> is full. Unable to log block <logical block address >."
Updated: May 11, 2026
ID: 000013499
VxRail: Event Code: VXR500PDR115
This event code indicates "The <PCIe solid state device name> is in read-only mode."
Updated: May 11, 2026
ID: 000013498
VxRail: vCenter machine ID mismatch
Updated: May 11, 2026
ID: 000455730
If the VxRail cluster has been upgraded from version 4.5.x to 7.0.240 or later, users must upgrade to newer releases and enable vSphere Lifecycle Management (vLCM).
Updated: May 11, 2026
ID: 000190895
This article provides information about how to collect the VxRail Manager log bundle on VxRail version 4.7.x and 7.x, 8.x, or using command line.
Updated: May 11, 2026
ID: 000190671
One or more VxRail Manager checks returns event code 1 or 2, for the dblogs test, representing a warning or fail, respectively. These must be investigated prior to upgrading the cluster.
Updated: May 11, 2026
ID: 000190593
A diagnostic warning event occurred in the memory device.
Updated: May 11, 2026
ID: 000184533
One or more memory errors have occurred during the Double Data Rate (DDR) memory channel initialization on the memory slot.
Updated: May 11, 2026
ID: 000184534
Unable to use the system memory because the DIMMs are populated in an unsupported (configuration) manner.
Updated: May 11, 2026
ID: 000184535
This is an iDRAC internal warning, indicating the Fibre Channel (FC) controller port link is down.
Updated: May 11, 2026
ID: 000184758
Dell VxRail: event VXR508MEM6114 A diagnostic warning event occurred in the memory device at <location>. Contact your service provider for assistance in replacing the device. (Extended ID: <code>).
Updated: May 11, 2026
ID: 000189212
VxRail appliance dials home to Dell EMC with event code VXR104205, indicating that VxRail Manager I2E desired configuration update operation failed.
Updated: May 11, 2026
ID: 000197176
Event VXR508PR39 is reported after replacing the PERC card.
Updated: May 11, 2026
ID: 000206256
Event VXR508STOR5001 is reported when an internal error in the storage library.
Updated: May 11, 2026
ID: 000206259
A power‑off occurs when the inlet temperature exceeds the critical limit because the alert action is configured to shut down; the temperature condition itself does not trigger an automatic shutdown.
Updated: May 11, 2026
ID: 000181231
Support new iDRAC events monitor: SEKM075. Event VXR508SEKM075 iDRAC is unable to switch from Local Key Management (iLKM) to Secure Enterprise Key Manager (SEKM)
Updated: May 11, 2026
ID: 000190286
iDRAC Service Module (iSM) versions 4.0.1 and earlier for VMware ESXi may stop functioning and the dcism service stop if the core hostd service of the ESXi host was recently restarted.
Updated: May 11, 2026
ID: 000190265
The intent of this KB is to provide the proper course of action to take in the event that the notified mystic code takes place.
Updated: May 11, 2026
ID: 000189612
Error shown in iDRAC virtual console "LIC501: A required license is missing or expired."
Updated: May 11, 2026
ID: 000189590
VxRail 7.0.130 or 4.7.525 or later graceful reboot and power on not completed successfully, vSAN cluster loses vSAN tag on VMkernel.
Updated: May 10, 2026
ID: 000189539
This article details how to confirm the build version of various VxRail components. This includes ESXi, vCenter Server Appliance, and VxRail Manager.
Updated: May 10, 2026
ID: 000189488
Event code: VXR508MEM0802 - DIMM degradation detected
Updated: May 10, 2026
ID: 000189457
Guide to resolve disk and power supply shown as N/A with VxRail 7.0.x Physical View.
Updated: May 10, 2026
ID: 000189161
One or more VxRail Manager checks returns an event code 1 or 2, representing yellow or red alerts, respectively. These must be investigated before conducting cluster activities (for example node expansion or upgrade).
Updated: May 10, 2026
ID: 000189003
On VxRail, false NIC100 and NIC101 events may be logged in Lifecycle Controller logs with Intel X710 family of adapters running firmware (FW) v19.5.12.
Updated: May 10, 2026
ID: 000188812