Dell PowerEdge T320 Getting Started Guide

Technical Specifications

  • NOTE: The following specifications are only those required by law to ship with your system. For a complete and current listing of the specifications for your system, go to support.dell.com.
Power
AC Power Supply (per power supply)  
  Wattage 350 W, 495 W, or 750 W
  Heat dissipation
  • NOTE: Heat dissipation is calculated using the power supply wattage rating.

1908 BTU/hr maximum (495 W power supply)

2891 BTU/hr maximum (750 W power supply)

1456 BTU/hr maximum (350 W non-redundant power supply)

  Voltage
  • NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.
100 V AC to 240 V AC, autoranging, 50 Hz/60 Hz
Battery  
  Coin-cell battery 3 V CR2032 Lithium coin cell
Physical
  Tower  
  Height 443.3 mm (17.45 inch) with feet

430.3 mm (16.94 inch) without feet

  Width 304.5 mm (11.99 inch) with feet opened

218 mm (8.58 inch) with feet closed

  Depth 542.2 mm (21.35 inch) without bezel

558.6 mm (21.99 inch) with bezel

  Rack  
  Height 218 mm (8.58 inch)
  Width

430.3 mm (16.94 inch) without ears

482.4 mm (18.99 inch) with ears

  Depth (minimum)

538.4 mm (21.2 inch) from back of rack ears and with cabled power supply module

  Depth (maximum)

584.05 mm (22.99 inch) from back of rack ears and with external system fan

Maximum configuration weight 29.55 kg (65.14 lb)
Empty weight 15.6 kg (34.39 lb)
Environmental  
  • NOTE: Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data centers. For more information, see the Owner's Manual.
  • NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Temperature  
  Operating Continuous operation: 10 °C to 35 °C. De-rate maximum allowable dry bulb temperature at 1 °C/300 m above 900 m (1°F /550 ft).
  • NOTE: For information on supported expanded operating temperature range and configurations, see support.dell.com/manuals.
  Storage –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour.
Relative humidity  
  Operating 10% to 80% relative humidity (RH), with 26 °C maximum dew point.
  Storage 5% to 95% relative humidity ambient with 33 °C (91 °F) maximum dew point.
Maximum vibration  
  Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
  Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum shock  
  Operating One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation.
  Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 22 G faired square wave pulse with velocity change at 200 inches/second (508 centimeters/second).

Altitude  
  Operating

–15.2 m to 3048 m (–50 to 10,000 ft).

  • NOTE: For altitudes above 2950 ft, the maximum operating temperature is derated 1 ºF/550 ft.
  Storage –15.2 m to 10,668 m (–50 ft to 35,000 ft).
Airborne contaminant level
  Class G1 as defined by ISA-S71.04-1985.