Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Command | Monitor Version 9.1 Reference Guide

PDF

Sample Get RAID settings

Below is a sample VBScript that contains details of the sample GetRAID settings.

'**********************************************************************

'*** Name: SampleGetRAIDSettings.vbs

'*** Purpose: To get the current list of BIOS Settings on a Dell OMCI 8.2.1 client.

'*** Usage: cscript.exe /nologo SampleGetRAIDSettings.vbs <systemname>

'*** This sample script is provided as an example only, and has not been

'*** tested, nor is warranted in any way by Dell; Dell disclaims any

'*** liability in connection therewith. Dell provides no technical

'*** support with regard to such scripting. For more information on WMI

'*** scripting, refer to applicable Microsoft documentation.

'**********************************************************************

'*** Declare variables

Dim objWMIService
Dim strComputerName
Dim strNameSpace
Dim strClassName 
Dim ColSystem 
Dim fso
Dim txtfile
Dim outString
Dim iTKVal 
Dim ArrayItem 
Dim objInstance 
Dim SupportedListCV(5) 
SupportedListCV(0) = "InstanceID"
SupportedListCV(1) = "PrimaryStatus"
SupportedListCV(2) = "ControllerFirmwareVersion"
SupportedListCV(3) = "BusType" 
SupportedListCV(4) = "Device"
SupportedListCV(5) = "ProductName" 

'*** Check that the right executable was used to run the script and that all parameters were passed

If (LCase(Right(WScript.FullName, 11)) = "wscript.exe" ) Or _ 
(Wscript.Arguments.Count < 1) Then 
Call Usage()
WScript.Quit 
End If 

'*** Initialize variables

Set fso = CreateObject("Scripting.FileSystemObject")
strComputerName = WScript.Arguments(0)
outString = "" 
strNameSpace = "root/dcim/sysman"
strClassName = "DCIM_ControllerView" 
iTKVal = -1
ArrayItem = 0

'*** Establish a connection to the dcim/sysman namespace

'*** Retrieve the instance of DCIM_ControllerView class

Set objWMIService = GetObject("winmgmts:{impersonationLevel=impersonate," &_
"AuthenticationLevel=pktprivacy}\\" & strComputerName & "\" &_
strNameSpace) 

'*** Set up the output file

set txtfile = fso.Createtextfile("RAID_Output.csv", true) 
Set ColSystem=objWMIService.execquery ("Select * from " & strClassName)
outString = "" 
For Each objItem in ColSystem 
For Each p in objItem.Properties_
For Each obj in SupportedListCV 
If p.Name = obj Then
' Display the values of the Name and Value properties of the SWbemProperty object 
outString = outString & p.Name & "," & p.Value & VbCrLf 
End If 
Next
Next 
Next 
txtfile.WriteLine outString

'*** Close the file

txtfile.close 

'*** If any errors occurred, let the user know

If Err.Number <> 0 Then 
WScript.Echo "Enabling Trusted Platform Module failed."
End If

'*** Sub used to display the correct usage of the script

Sub Usage()
Dim strMessage 
strMessage = "incorrect syntax. You should run: " & vbCRLF & _ 
"cscript.exe /nologo SampleGetRAIDSettings.vbs <systemname>"
WScript.Echo strMessage 
End Sub

'==========================================================================

' End

'==========================================================================