Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Dell OpenManage Deployment Toolkit Version 4.3 Command Line Interface Reference Guide

PDF

Failures And Solutions

The following table lists the common SYSCFG failures and their solution.

Table 1. SYSCFG Failures and Solutions
Failure Messages Solutions
Generic failure. Indicates iDRAC is in bad state. Reboot iDRAC.
New value not valid. Make sure the changed value is valid.
Cannot disable this orderedList’s entries. BIOS does not support enabling or disabling of a particular boot order object.
System busy, try again later. Retry as iDRAC is busy with internal processing.
Unable to connect IDRAC data manager. Start data manager service using srvadmin_services (specific to Linux).
System Services and/or CSIOR disabled. Enable CSIOR from <F2> screen.