Description
The controller write policy has been changed to Write Through.
Severity
Warning
Cause and Action
Cause: The controller battery is unable to maintain cached data for the required period of time. For example, if the required period of time is 24 hours, the battery is unable to maintain cached data for 24 hours. It is normal to receive this alert during the battery Learn cycle as the Learn cycle discharges the battery before recharging it. When discharged, the battery cannot maintain cached data.

Action: Check the health of the battery. If the battery is weak, replace the battery pack.