Dell OpenManage SNMP Reference Guide Version 8.2

PDF

BIOS Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.
Table 1. Speaker Control Capabilities Unique
Variable Name: DellSpeakerControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Speaker control capabilities are unknown.
enableCapable(2) Setup BIOS can enable speaker control.
lowCapable(4) Setup BIOS can set the speaker volume to low.
mediumCapable(8) Setup BIOS can set the speaker volume to medium.
highCapable(16) Setup BIOS can set the speaker volume to high.
allVolumeCapable(30) Setup BIOS can set the speaker volume to any of the three settings.
Table 2. Speaker Control Settings Unique
Variable Name: DellSpeakerControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Speaker control state is unknown.
enabled(2) Speaker control is enabled.
low(4) Speaker control volume is low.
medium(8) Speaker control volume is medium.
high(16) Speaker control volume is high.
Table 3. Network Interface (NIF) Wakeup on LAN Capabilities Unique
Variable Name: DellNIFwakeonLanControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown.
enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN.
addInCardCapable(4) Setup BIOS is capable of enabling Wakeup on LAN by option card.
onBoardCapable(8) Setup BIOS is capable of enabling Wakeup on LAN by integrated NIF.
bothCapable(14) Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIF.
Table 4. NIF Wakeup on LAN Control Settings Unique
Variable Name: DellNIFwakeonLanControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) NIF Wakeup on LAN state is unknown.
enabled(2) NIF Wakeup on LAN is enabled.
addInCard(4) NIF Wakeup on LAN is by option card.
onBoard(8) NIF Wakeup on LAN is by integrated NIF.
addInCardOrOnBoard(12) NIF Wakeup on LAN is by option card or integrated NIF.
Table 5. Boot Sequence Control Capabilities Unique
Variable Name: DellBootSequenceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
bootSequenceUnknown(1) Boot sequence capabilities are unknown.
bootFromDisketteFirstCapable (2) Setup BIOS can boot from a diskette first.
bootFromhardDriveFirstCapable (4) Setup BIOS can boot from an IDE hard drive first.
bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot from a diskette or an IDE hard drive first.
bootFromDeviceListCapable(8) Setup BIOS can boot from a device list.
bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first.
allFirstCapable(30) Setup BIOS can boot by any of the preceding methods first.
Table 6. Boot Sequence Control Settings Unique
Variable Name: DellBootSequenceControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
bootSequenceUnknown(1) Boot sequence state is unknown.
bootFromDisketteFirst(2) Setup BIOS is set to boot by diskette first.
bootFromHardDriveFirst(4) Setup BIOS is set to boot by IDE hard drive first.
bootFromDeviceList(8) Setup BIOS is set to boot by a device list.
bootFromCDROMFirst(16) Setup BIOS is set to boot by CD first.
Table 7. BIOS Password Control Capabilities
Variable Name: DellBIOSPasswordControlCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
passwordControlCapabilitiesUn known(1) BIOS password capabilities are unknown.
passwordControlEnableCapable (2) Setup BIOS is capable of enabling password changes.
passwordControlJumperDisable Capable(4) Setup BIOS is capable of determining if password control can be jumper disabled.
passwordControlEnableANDJumper DisableCapable(6) Setup BIOS is capable of enabling password changes and of determining if password control can be jumper disabled.
Table 8. BIOS Password Control Settings Unique
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
passwordControlSettingsUnknown(1) Setup BIOS password state is unknown.
passwordControlEnabled(2) Setup BIOS has password changes enabled.
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper.
Table 9. BIOS Password Control Settings
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
passwordControlSettingsUnknown(1) Setup BIOS password state is unknown.
passwordControlEnabled(2) Setup BIOS has password changes enabled.
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper.
Table 10. TPM Security Control Capabilities
Variable Name: DellTPMSecurityControlCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
offCapable(1) TPM security can be Off.
onWithPrebootMeasurementsCap able(2) TPM security can be On with Pre-boot Measurements.
onWithoutPrebootMeasurements Capable(4) TPM security can be On without Pre-boot Measurements.
Table 11. TPM Security Control Setting
Variable Name: DellTPMSecurityControlSetting
Data Type: Integer
Possible Data Values Meaning of Data Value
off(0) TPM security is Off.
onWithPrebootMeasurements(1) TPM security is On with Pre-boot Measurements.
onWithoutPrebootMeasurements (2) TPM security is On without Pre-boot Measurements.
Table 12. Parallel Port Control Capabilities
Variable Name: DellParallelPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Setup BIOS parallel port capabilities are unknown.
enableCapable(2) Setup BIOS can enable the parallel port.
lpt1Capable(4) Setup BIOS can support parallel port 1.
lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1.
lpt2Capable(8) Setup BIOS can support parallel port 2.
lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2.
lpt3Capable(16) Setup BIOS can support parallel port 3.
lpt3andEnableCapable(18) Setup BIOS has enabled parallel port 3.
allParallelPortCapable(30) Setup BIOS can support any of the three parallel ports.
Table 13. Parallel Port Control Settings
Variable Name: DellParallelPortControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Parallel port state is unknown.
enabled(2) Setup BIOS has enabled the parallel port.
lpt1(4) Setup BIOS supports parallel port 1.
lpt1Enabled(6) Setup BIOS has enabled parallel port 1.
lpt2(8) Setup BIOS supports parallel port 2.
lpt2Enabled(10) Setup BIOS has enabled parallel port 2.
lpt3(16) Setup BIOS supports parallel port 3.
Table 14. Parallel Port Control Mode Settings
Variable Name: DellParallelPortControlModeSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Parallel port mode is unknown.
atModeEnabled(2) Setup BIOS has set the parallel port to AT mode.
ps2ModeEnabled(4) Setup BIOS has set the parallel port to Personal Systems/2 (PS/2) mode.
ecpModeEnabled(8) Setup BIOS has set the parallel port to Extended Capabilities Port (ECP) mode.
eppModeEnabled(16) Setup BIOS has set the parallel port to Enhanced Parallel Port (EPP) mode.
Table 15. Serial Port Control Capabilities
Variable Name: DellSerialPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Setup BIOS serial port capabilities are unknown.
enableCapable(2) Setup BIOS can enable the serial port.
com1Capable(4) Setup BIOS can support serial port 1.
enableAndCom1Capable(6) Setup BIOS can enable serial port 1.
com2Capable(8) Setup BIOS can support serial port 2.
enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2.
com3Capable(16) Setup BIOS can support serial port 3.
enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3.
com4Capable(32) Setup BIOS can support serial port 4.
enableAndCom4Capable(34) Setup BIOS is capable of enabling serial port 4.
autoConfigCapable(64) Setup BIOS is capable of autoconfiguring all serial ports.
com1OrCom3CapableAndAuto ConfigCapable(86) Setup BIOS has enabled autoconfiguration of COM1 and COM3 serial ports.
com2OrCom4CapableAndAuto ConfigCapable(106) Setup BIOS has enabled autoconfiguration of COM2 and COM4 serial ports.
allcomCapable(126) Setup BIOS is capable of enabling or autoconfiguring all serial ports.
Table 16. Serial Port Control Settings
Variable Name: DellSerialPortControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Serial port state is unknown.
enabled(2) Setup BIOS has enabled the serial port.
com1(4) Setup BIOS has selected serial port 1.
com1Enabled(6) Setup BIOS has enabled serial port 1.
com2(8) Setup BIOS has selected serial port 2.
com2Enabled(10) Setup BIOS has enabled serial port 2.
com3(16) Setup BIOS has selected serial port 3.
com3Enabled(18) Setup BIOS has enabled serial port 3.
com4(32) Setup BIOS has selected serial port 4.
com4Enabled(34) Setup BIOS has enabled serial port 4.
comPortsAutoConfig(64) Setup BIOS has selected autoconfiguration of serial ports.
enabledAndAutoConfig(66) Setup BIOS has enabled autoconfiguration of serial ports.
Table 17. IDE Control Capabilities
Variable Name: DellideControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) IDE control capabilities are unknown.
ideControlAutoConfigOrEnable Capable(2) IDE controller is autoconfigurable or enable capable.
Table 18. Diskette Control Settings
Variable Name: DellDisketteControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Diskette control state is unknown.
disketteControlAutoConfigEnabled OrEnabled(2) Diskette control is set as autoconfigurable or enabled.
Table 19. Network Interface Control Capabilities
Variable Name: DellNetworkInterfaceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Unknown setup BIOS network interface capabilities.
enableCapable(2) Setup BIOS is capable of enabling the network interface.
enableWithoutPXECapable(4) Setup BIOS is capable of enabling the NIF without Pre-boot eXecution Environment (PXE).
Table 20. Network Interface Control Settings
Variable Name: DellNetworkInterfaceControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Network interface state is unknown.
enabled(2) Network interface is enabled.
enabledWithoutPXE(4) Network interface is enabled without PXE.
Table 21. BIOS Setting Value Type
Variable Name: DellBIOSSettingValueType
Data Type: Integer
Possible Data Values Meaning of Data Value
integer(1) Value type is integer.
string(2) Value type is string.
enumeration(3) Value type is enumeration.
orderedList(4) Value type is ordered list.

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\